» Articles » PMID: 36296151

Electrochemical Testing of a New Polyimide Thin Film Electrode for Stimulation, Recording, and Monitoring of Brain Activity

Overview
Publisher MDPI
Date 2022 Oct 27
PMID 36296151
Authors
Affiliations
Soon will be listed here.
Abstract

Subdural electrode arrays are used for monitoring cortical activity and functional brain mapping in patients with seizures. Until recently, the only commercially available arrays were silicone-based, whose thickness and lack of conformability could impact their performance. We designed, characterized, manufactured, and obtained FDA clearance for 29-day clinical use (510(k) K192764) of a new thin-film polyimide-based electrode array. This study describes the electrochemical characterization undertaken to evaluate the quality and reliability of electrical signal recordings and stimulation of these new arrays. Two testing paradigms were performed: a short-term active soak with electrical stimulation and a 29-day passive soak. Before and after each testing paradigm, the arrays were evaluated for their electrical performance using Electrochemical Impedance Spectroscopy (EIS), Cyclic Voltammetry (CV) and Voltage Transients (VT). In all tests, the impedance remained within an acceptable range across all frequencies. The different CV curves showed no significant changes in shape or area, which is indicative of stable electrode material. The electrode polarization remained within appropriate limits to avoid hydrolysis.

Citing Articles

Challenges and opportunities of acquiring cortical recordings for chronic adaptive deep brain stimulation.

Herron J, Kullmann A, Denison T, Goodman W, Gunduz A, Neumann W Nat Biomed Eng. 2024; .

PMID: 39730913 DOI: 10.1038/s41551-024-01314-3.


Polyimide as a biomedical material: advantages and applications.

Shu J, Zhou Z, Liang H, Yang X Nanoscale Adv. 2024; 6(17):4309-4324.

PMID: 39170974 PMC: 11334982. DOI: 10.1039/d4na00292j.

References
1.
Merrill D, Bikson M, Jefferys J . Electrical stimulation of excitable tissue: design of efficacious and safe protocols. J Neurosci Methods. 2005; 141(2):171-98. DOI: 10.1016/j.jneumeth.2004.10.020. View

2.
Sacino M, Huang S, Schreiber J, Gaillard W, Oluigbo C . Is the use of Stereotactic Electroencephalography Safe and Effective in Children? A Meta-Analysis of the use of Stereotactic Electroencephalography in Comparison to Subdural Grids for Invasive Epilepsy Monitoring in Pediatric Subjects. Neurosurgery. 2018; 84(6):1190-1200. DOI: 10.1093/neuros/nyy466. View

3.
Punia V, Bulacio J, Gonzalez-Martinez J, Abdelkader A, Bingaman W, Najm I . Extra operative intracranial EEG monitoring for epilepsy surgery in elderly patients. Epilepsy Behav Case Rep. 2018; 10:92-95. PMC: 6092550. DOI: 10.1016/j.ebcr.2018.07.002. View

4.
Roland J, Brunner P, Johnston J, Schalk G, Leuthardt E . Passive real-time identification of speech and motor cortex during an awake craniotomy. Epilepsy Behav. 2010; 18(1-2):123-8. DOI: 10.1016/j.yebeh.2010.02.017. View

5.
Van Gompel J, Worrell G, Bell M, Patrick T, Cascino G, Raffel C . Intracranial electroencephalography with subdural grid electrodes: techniques, complications, and outcomes. Neurosurgery. 2008; 63(3):498-505. DOI: 10.1227/01.NEU.0000324996.37228.F8. View