» Articles » PMID: 35539903

Dual Dye-loaded Au@Ag Coupled to a Lateral Flow Immunoassay for the Accurate and Sensitive Detection of Infection

Overview
Journal RSC Adv
Specialty Chemistry
Date 2022 May 11
PMID 35539903
Authors
Affiliations
Soon will be listed here.
Abstract

We present an attractive model of surface-enhanced Raman scattering-based lateral flow immunoassay (SERS-LFIA) for the sensitive and accurate detection of (MP) infection in human serum. The SERS-LFIA strip uses Au@Ag nanoparticles (Au@Ag NPs) loaded with two layers of Raman dye 5,5'-dithiobis-(2-nitrobenzoic acid) (DTNB) as SERS tags. The advantages of the dual dye-loaded SERS tags (Au/DTNB@Ag/DTNB) are the high sensitivity and the bioconjugation flexibility of the detection antibody. As determined from our SERS-LFIA strip, human IgM was quantified by monitoring the SERS signal on the test line. The limit of detection for human IgM was 0.1 ng mL, which was 100 times more sensitive than that by using the colorimetric method. Our assay results for 20 MP-specific IgM positive serum specimens showed 100% accuracy and detection rate, whereas the parallel enzyme-linked immunosorbent assay only showed 85% detection rate. The SERS-LFIA strip also exhibited high specificity and potential clinical applications. Therefore, our SERS-based LFIA strip has strong potential for practical applications in the sensitive and rapid detection of MP.

Citing Articles

Research Progress in Small-Molecule Detection Using Aptamer-Based SERS Techniques.

Zheng L, Ye Q, Wang M, Sun F, Chen Q, Yu X Biosensors (Basel). 2025; 15(1).

PMID: 39852080 PMC: 11764255. DOI: 10.3390/bios15010029.


Sensing the Future-Frontiers in Biosensors: Exploring Classifications, Principles, and Recent Advances.

Manoharan Nair Sudha Kumari S, Thankappan Suryabai X ACS Omega. 2024; 9(50):48918-48987.

PMID: 39713646 PMC: 11656264. DOI: 10.1021/acsomega.4c07991.


Establishment of a Raman microsphere-based immunochromatographic method for the combined detection of influenza A and B viruses and SARS-CoV-2 antigen on a single T-line.

Zhu A, Zhao B, Li J, Li X, Shi Q, Zhang X RSC Adv. 2024; 14(50):37498-37511.

PMID: 39582936 PMC: 11582967. DOI: 10.1039/d4ra05483k.


Development of aptamer surface-enhanced Raman spectroscopy sensor based on FeO@Pt and Au@Ag nanoparticles for the determination of acetamiprid.

Dong S, Zhu Z, Shi Q, He K, Wu J, Feng J Mikrochim Acta. 2024; 191(5):289.

PMID: 38683210 DOI: 10.1007/s00604-024-06351-y.


Immunoassays: Analytical and Clinical Performance, Challenges, and Perspectives of SERS Detection in Comparison with Fluorescent Spectroscopic Detection.

Terzapulo X, Kassenova A, Bukasov R Int J Mol Sci. 2024; 25(4).

PMID: 38396756 PMC: 10889711. DOI: 10.3390/ijms25042080.


References
1.
Wu F, Yuan H, Zhou C, Mao M, Liu Q, Shen H . Multiplexed detection of influenza A virus subtype H5 and H9 via quantum dot-based immunoassay. Biosens Bioelectron. 2015; 77:464-70. PMC: 7126372. DOI: 10.1016/j.bios.2015.10.002. View

2.
Su J, Wang D, Norbel L, Shen J, Zhao Z, Dou Y . Multicolor Gold-Silver Nano-Mushrooms as Ready-to-Use SERS Probes for Ultrasensitive and Multiplex DNA/miRNA Detection. Anal Chem. 2017; 89(4):2531-2538. DOI: 10.1021/acs.analchem.6b04729. View

3.
Shao L, Zhang A, Rong Z, Wang C, Jia X, Zhang K . Fast and non-invasive serum detection technology based on surface-enhanced Raman spectroscopy and multivariate statistical analysis for liver disease. Nanomedicine. 2017; 14(2):451-459. DOI: 10.1016/j.nano.2017.11.022. View

4.
Lee S, Youn Y, Rhim J, Kang J, Lee K . Early Serologic Diagnosis of Mycoplasma pneumoniae Pneumonia: An Observational Study on Changes in Titers of Specific-IgM Antibodies and Cold Agglutinins. Medicine (Baltimore). 2016; 95(19):e3605. PMC: 4902508. DOI: 10.1097/MD.0000000000003605. View

5.
Stambach N, Carr S, Cox C, Voorhees K . Rapid Detection of Listeria by Bacteriophage Amplification and SERS-Lateral Flow Immunochromatography. Viruses. 2015; 7(12):6631-41. PMC: 4690885. DOI: 10.3390/v7122962. View