» Articles » PMID: 35360735

Is It a "Colon Perforation"? A Case Report and Review of the Literature

Abstract

Background: Intrauterine devices (IUDs) are commonly used as a contraceptive method. IUD migration and colon perforation are rare but serious complications occurring sometimes years after insertion.

Case: A 42-year-old woman with complaints of slight abdominal pain underwent a colonoscopy. Colonoscopy showed that a "nail" had penetrated the ascending colon wall and that an arm of the "nail" was embedded in the colon wall. We did not remove the "nail" rashly under colonoscopy. Considering the safety and effectiveness of the patient's operation, we were able to remove the "nail" easily by performing laparoscopic-endoscopic cooperative surgery (LECS) combined with hysteroscopy at the same time.

Conclusion: We report a case of successful removal of a colonic perforation device by colonoscopy, laparoscopy, and hysteroscopy, which is the first method used.

Citing Articles

Open surgical retrieval of intra-uterine contraceptive device perforating the ileum: A case report.

Almatary A, Alsharif A, Ghabisha S, Ahmed F, Badheeb M Int J Surg Case Rep. 2023; 109:108635.

PMID: 37552923 PMC: 10425888. DOI: 10.1016/j.ijscr.2023.108635.

References
1.
Zeino M, Wietfeldt E, Advani V, Ahad S, Younkin C, Hassan I . Laparoscopic removal of a copper intrauterine device from the sigmoid colon. JSLS. 2012; 15(4):568-70. PMC: 3340974. DOI: 10.4293/108680811X13176785204661. View

2.
Tabatabaei F, Masoumzadeh M . Dislocated intrauterine devices: clinical presentations, diagnosis and management. Eur J Contracept Reprod Health Care. 2021; 26(2):160-166. DOI: 10.1080/13625187.2021.1874337. View

3.
Agha R, Fowler A, Saeta A, Barai I, Rajmohan S, Orgill D . The SCARE Statement: Consensus-based surgical case report guidelines. Int J Surg. 2016; 34:180-186. DOI: 10.1016/j.ijsu.2016.08.014. View

4.
Mederos R, Humaran L, Minervini D . Surgical removal of an intrauterine device perforating the sigmoid colon: a case report. Int J Surg. 2007; 6(6):e60-2. DOI: 10.1016/j.ijsu.2007.02.006. View

5.
Nceboz U, Ozcakir H, Uyar Y, Caglar H . Migration of an intrauterine contraceptive device to the sigmoid colon: a case report. Eur J Contracept Reprod Health Care. 2004; 8(4):229-32. View