» Articles » PMID: 33555216

Dislocated Intrauterine Devices: Clinical Presentations, Diagnosis and Management

Overview
Publisher Informa Healthcare
Date 2021 Feb 8
PMID 33555216
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: Intrauterine devices (IUDs) are globally one of the most popular methods of contraception. Uterine perforation is one of the most significant complications of IUD use and commonly occurs at the time of IUD insertion rather than presenting as delayed migration. This paper reports a series of 13 cases of displaced IUDs requiring retrieval by laparoscopy or laparotomy. All the IUDs were copper bearing and most perforations occurred immediately after IUD insertion.

Cases: In two patients with sigmoid colon injury and IUD penetration of the appendix, laparoscopic management had failed and laparotomy was necessary owing to severe obliteration of the pelvic cavity. In one patient laparotomy was the preferred surgical approach owing to acute bowel perforation. In the remaining patients, the displaced devices were successfully removed by laparoscopy.

Conclusion: Uterine perforation and IUD migration to the organs in the abdominopelvic cavity are serious complications of IUD insertion and can be successfully managed by laparoscopy, or by laparotomy in the presence of severe pelvic adhesions or unexpected complications.

Citing Articles

Removal of an incarcerated intrauterine device reaching the serosal surface of the uterus by hysteroscopy alone: a case report.

You M, Chen Q, Lu H Front Med (Lausanne). 2025; 11():1486745.

PMID: 39839653 PMC: 11747293. DOI: 10.3389/fmed.2024.1486745.


Intrauterine Contraceptive Device Translocation Leading to Right Anteromedial Ovarian Surface Impingement and Laparoscopic Retrieval: A Case Report and Literature Review.

Anwaar A, Karamat R, Khanzada M, Akilimali A, Aamir M, Arshad M Clin Case Rep. 2025; 13(1):e70061.

PMID: 39776775 PMC: 11705494. DOI: 10.1002/ccr3.70061.


Migration of Intrauterine Device Into the Bladder: A Case Report.

Xue Q, Chai M, Zhang J, Liu S, Duan D Cureus. 2024; 16(10):e72361.

PMID: 39588399 PMC: 11586876. DOI: 10.7759/cureus.72361.


Evaluation of uterocervical angle in intrauterine device displacement cases.

Dincgez B, Ketenci Gencer F Arch Gynecol Obstet. 2024; 310(6):3165-3171.

PMID: 39570386 DOI: 10.1007/s00404-024-07823-5.


Risk factors of uterine perforation when using contraceptive intrauterine devices.

Tabatabaei F, Hosseini S, Hakimi P, Vejdani R, Khademi B BMC Womens Health. 2024; 24(1):538.