Effect of CZT System Characteristics on Compton Scatter Event Recovery

Overview
Publisher IEEE
Date 2020 Jan 11
PMID 31922083
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Improving 511 keV photon detection sensitivity is a common goal for positron emission tomography system designers. One attractive approach to increase sensitivity is recovering events that are normally rejected. The kinematics of Compton scattering can be used to recover the line of response through direction difference angle (DDA). The uncertainty of DDA is determined by the energy and spatial resolution of a system. In this work, we evaluated the performance of small animal CZT-based positron emission tomography systems with energy resolution of 1%, 4%, and 6% and different spatial resolution based on prior work for guiding new design efforts. Designs with energy resolution limited by counting statistics and by electronic noise were considered. The influence of modifying the conventional energy window and uncertainty of DDA was investigated. For a system with 4% energy resolution and limited by electronic noise, the figure of merit of noise equivalent count increases by 65% as the lower energy bound increases from 471 keV to 493 keV. If the system-wide energy resolution becomes worse than 4% of the full width half maximum at 511 keV, going to a pixel size finer than 1 mm has very limited effect in reducing total angular uncertainty. For a system with 1% energy resolution, as the spatial resolution improves from 1 mm to 0.5 mm, the contrast-to-noise ratio increases by 9%.

Citing Articles

Quantum Entanglement Filtering: A PET feasibility study in imaging dual-positron and prompt gamma emission via Monte Carlo simulation.

Romanchek G, Shoop G, Gholami K, Enlow E, Abbaszadeh S IEEE Trans Radiat Plasma Med Sci. 2024; 8(8):916-925.

PMID: 39507126 PMC: 11540415. DOI: 10.1109/trpms.2024.3388872.


Back-end readout electronic design and initial results: a head-and-neck dedicated PET system based on CZT.

Wang Y, Herbst R, Abbaszadeh S Proc SPIE Int Soc Opt Eng. 2024; 11595.

PMID: 39493263 PMC: 11530711. DOI: 10.1117/12.2576598.


Experimental Evaluation of a 3-D CZT Imaging Spectrometer for Potential Use in Compton-Enhanced PET Imaging.

Jin Y, Streicher M, Yang H, Brown S, He Z, Meng L IEEE Trans Radiat Plasma Med Sci. 2023; 7(1):18-32.

PMID: 38106623 PMC: 10723109. DOI: 10.1109/trpms.2022.3200010.


Development and Characterization of Modular Readout Design for Two-Panel Head-and-Neck Dedicated PET System Based on CZT Detectors.

Wang Y, Herbst R, Abbaszadeh S IEEE Trans Radiat Plasma Med Sci. 2023; 6(5):517-521.

PMID: 37711549 PMC: 10500713. DOI: 10.1109/trpms.2021.3111547.


Design study of a dedicated head and neck cancer PET system.

Li M, Yockey B, Abbaszadeh S IEEE Trans Radiat Plasma Med Sci. 2020; 4(4):489-497.

PMID: 32632397 PMC: 7337125. DOI: 10.1109/trpms.2020.2964293.

References
1.
Abbaszadeh S, Gu Y, Reynolds P, Levin C . Characterization of a sub-assembly of 3D position sensitive cadmium zinc telluride detectors and electronics from a sub-millimeter resolution PET system. Phys Med Biol. 2016; 61(18):6733-6753. DOI: 10.1088/0031-9155/61/18/6733. View

2.
Wang Y, Seidel J, Tsui B, Vaquero J, Pomper M . Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner. J Nucl Med. 2006; 47(11):1891-900. View

3.
Levin C, Foudray A, Habte F . Impact of high energy resolution detectors on the performance of a PET system dedicated to breast cancer imaging. Phys Med. 2007; 21 Suppl 1:28-34. DOI: 10.1016/S1120-1797(06)80020-7. View

4.
Schaart D, van Dam H, Seifert S, Vinke R, Dendooven P, Lohner H . A novel, SiPM-array-based, monolithic scintillator detector for PET. Phys Med Biol. 2009; 54(11):3501-12. DOI: 10.1088/0031-9155/54/11/015. View

5.
Espana S, Marcinkowski R, Keereman V, Vandenberghe S, Van Holen R . DigiPET: sub-millimeter spatial resolution small-animal PET imaging using thin monolithic scintillators. Phys Med Biol. 2014; 59(13):3405-20. DOI: 10.1088/0031-9155/59/13/3405. View