Performance Measurements of a Depth-encoding PET Detector Module Based on Position-sensitive Avalanche Photodiode Read-out

Overview
Journal Phys Med Biol
Publisher IOP Publishing
Date 2004 Oct 29
PMID 15509066
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

We are developing a high-resolution, high-efficiency positron emission tomography (PET) detector module with depth of interaction (DOI) capability based on a lutetium oxyorthosilicate (LSO) scintillator array coupled at both ends to position-sensitive avalanche photodiodes (PSAPDs). In this paper we present the DOI resolution, energy resolution and timing resolution results for complete detector modules. The detector module consists of a 7 x 7 matrix of LSO scintillator crystals (1 x 1 x 20 mm3 in dimension) coupled to 8 x 8 mm2 PSAPDs at both ends. Flood histograms were acquired and used to generate crystal look-up tables. The DOI resolution was measured for individual crystals within the array by using the ratio of the signal amplitudes from the two PSAPDs on an event-by-event basis. A measure of the total scintillation light produced was obtained by summing the signal amplitudes from the two PSAPDs. This summed signal was used to measure the energy resolution. The DOI resolution was measured to be 3-4 mm FWHM irrespective of the position of the crystal within the array, or the interaction location along the length of the crystal. The total light signal and energy resolution was almost independent of the depth of interaction. The measured energy resolution averaged 14% FWHM. The coincidence timing resolution measured using a pair of identical detector modules was 4.5 ns FWHM. These results are consistent with the design goals and the performance required of a compact, high-resolution and high-efficiency PET detector module for small animal and breast imaging applications.

Citing Articles

Effect of CZT system characteristics on Compton scatter event recovery.

Yang S, Li M, Reed M, Hugg J, Chen H, Abbaszadeh S IEEE Trans Radiat Plasma Med Sci. 2020; 4(1):91-97.

PMID: 31922083 PMC: 6952068. DOI: 10.1109/TRPMS.2019.2915054.


Depth-of-interaction study of a dual-readout detector based on TOFPET2 application-specific integrated circuit.

Li M, Abbaszadeh S Phys Med Biol. 2019; 64(17):175008.

PMID: 31382253 PMC: 7239556. DOI: 10.1088/1361-6560/ab3866.


Innovations in Instrumentation for Positron Emission Tomography.

Eric Berg , Cherry S Semin Nucl Med. 2018; 48(4):311-331.

PMID: 29852942 PMC: 5986096. DOI: 10.1053/j.semnuclmed.2018.02.006.


Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout.

Ren S, Yang Y, Cherry S Med Phys. 2014; 41(7):072503.

PMID: 24989406 PMC: 4187348. DOI: 10.1118/1.4881097.


Efficient one-pair experimental system for spatial resolution demonstration of prototype PET detectors.

Tashima H, Yoshida E, Hirano Y, Nishikido F, Inadama N, Murayama H Radiol Phys Technol. 2014; 7(2):379-86.

PMID: 24938490 DOI: 10.1007/s12194-014-0276-z.