» Articles » PMID: 22412323

Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2012 Mar 14
PMID 22412323
Citations 67
Authors
Affiliations
Soon will be listed here.
Abstract

Over the last decade, cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) wide band gap semiconductors have attracted increasing interest as X-ray and gamma ray detectors. Among the traditional high performance spectrometers based on silicon (Si) and germanium (Ge), CdTe and CdZnTe detectors show high detection efficiency and good room temperature performance and are well suited for the development of compact and reliable detection systems. In this paper, we review the current status of research in the development of CdTe and CdZnTe detectors by a comprehensive survey on the material properties, the device characteristics, the different techniques for improving the overall detector performance and some major applications. Astrophysical and medical applications are discussed, pointing out the ongoing Italian research activities on the development of these detectors.

Citing Articles

Highly stable bismuth-chloride perovskite X-ray direct detectors with an ultralow detection limit.

Chen H, Han Q, Qin H, Shen Y, Lv H, Liu Y Chem Sci. 2025; 16(11):4768-4774.

PMID: 39958642 PMC: 11822846. DOI: 10.1039/d5sc00061k.


A Simulation Study for Optimal Pinhole Collimator Design in Gamma Camera Systems.

Ghoneim M J Med Phys. 2025; 49(4):648-653.

PMID: 39926144 PMC: 11801103. DOI: 10.4103/jmp.jmp_127_24.


Investigations on the Performance of a 5 mm CdTe Timepix3 Detector for Compton Imaging Applications.

Useche Parra J, Roque G, Schutz M, Fiederle M, Procz S Sensors (Basel). 2025; 24(24.

PMID: 39771709 PMC: 11679083. DOI: 10.3390/s24247974.


First Stability Characterization for a CZT Detection System in an ee Collider Environment.

Abbene L, Artibani F, Bettelli M, Buttacavoli A, Principato F, Zappettini A Sensors (Basel). 2024; 24(23).

PMID: 39686098 PMC: 11644527. DOI: 10.3390/s24237562.


Revolutionizing X-ray Imaging: A Leap toward Ultra-Low-Dose Detection with a Cascade-Engineered Approach.

Song X, Zhang X, He T, Wang J, Zhu H, Zhou R ACS Cent Sci. 2024; 10(11):2082-2089.

PMID: 39634221 PMC: 11613229. DOI: 10.1021/acscentsci.4c01296.


References
1.
Barrett , Eskin , Barber . Charge transport in arrays of semiconductor gamma-ray detectors. Phys Rev Lett. 1995; 75(1):156-159. DOI: 10.1103/PhysRevLett.75.156. View

2.
Birch R, Marshall M . Computation of bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detector. Phys Med Biol. 1979; 24(3):505-17. DOI: 10.1088/0031-9155/24/3/002. View

3.
Miyajima S . Thin CdTe detector in diagnostic x-ray spectroscopy. Med Phys. 2003; 30(5):771-7. DOI: 10.1118/1.1566388. View

4.
Miyajima S, Imagawa K, Matsumoto M . CdZnTe detector in diagnostic x-ray spectroscopy. Med Phys. 2002; 29(7):1421-9. DOI: 10.1118/1.1485975. View

5.
Lewellen T . Recent developments in PET detector technology. Phys Med Biol. 2008; 53(17):R287-317. PMC: 2891023. DOI: 10.1088/0031-9155/53/17/R01. View