» Articles » PMID: 31010184

A Comparison of Reflective Photoplethysmography for Detection of Heart Rate, Blood Oxygen Saturation, and Respiration Rate at Various Anatomical Locations

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2019 Apr 24
PMID 31010184
Citations 33
Authors
Affiliations
Soon will be listed here.
Abstract

Monitoring of vital signs is critical for patient triage and management. Principal assessments of patient conditions include respiratory rate heart/pulse rate and blood oxygen saturation. However, these assessments are usually carried out with multiple sensors placed in different body locations. The aim of this paper is to identify a single location on the human anatomy whereby a single 1 cm × 1 cm non-invasive sensor could simultaneously measure heart rate (HR), blood oxygen saturation (SpO), and respiration rate (RR), at rest and while walking. To evaluate the best anatomical location, we analytically compared eight anatomical locations for photoplethysmography (PPG) sensors simultaneously acquired by a single microprocessor at rest and while walking, with a comparison to a commercial pulse oximeter and respiration rate ground truth. Our results show that the forehead produced the most accurate results for HR and SpO both at rest and walking, however, it had poor RR results. The finger recorded similar results for HR and SpO, however, it had more accurate RR results. Overall, we found the finger to be the best location for measurement of all three parameters at rest; however, no site was identified as capable of measuring all parameters while walking.

Citing Articles

A finer-grained high altitude EEG dataset for hypoxia levels assessment.

Si Y, Zhang Y, Zhang X, Liu S, Zhang H, Yang H Sci Data. 2024; 11(1):1352.

PMID: 39695125 PMC: 11655562. DOI: 10.1038/s41597-024-04102-5.


A Review on Assisted Living Using Wearable Devices.

Iadarola G, Mengarelli A, Crippa P, Fioretti S, Spinsante S Sensors (Basel). 2024; 24(23).

PMID: 39685975 PMC: 11644744. DOI: 10.3390/s24237439.


A Novel Chest-Based PPG Measurement System.

Lin Q, Wang H, Biswas D, Li Z, Lutin E, Van Hoof C IEEE J Transl Eng Health Med. 2024; 12:675-683.

PMID: 39559824 PMC: 11573410. DOI: 10.1109/JTEHM.2024.3471468.


The behavioral and physiological correlates of affective mood switching in premenstrual dysphoric disorder.

Brown R, Bondy E, Prim J, Dichter G, Schiller C Front Psychiatry. 2024; 15:1448914.

PMID: 39559281 PMC: 11570288. DOI: 10.3389/fpsyt.2024.1448914.


Comparing peripheral limb and forehead vital sign monitoring in newborn infants at birth.

Swamy S, Stockwell S, Liu C, Henry C, Shipley L, Ward C Pediatr Res. 2024; .

PMID: 39420152 DOI: 10.1038/s41390-024-03651-0.


References
1.
Johansson A, Oberg P . Estimation of respiratory volumes from the photoplethysmographic signal. Part I: Experimental results. Med Biol Eng Comput. 1999; 37(1):42-7. DOI: 10.1007/BF02513264. View

2.
Johansson A, Oberg P . Estimation of respiratory volumes from the photoplethysmographic signal. Part 2: A model study. Med Biol Eng Comput. 1999; 37(1):48-53. DOI: 10.1007/BF02513265. View

3.
Nilsson L, Johansson A, Kalman S . Macrocirculation is not the sole determinant of respiratory induced variations in the reflection mode photoplethysmographic signal. Physiol Meas. 2003; 24(4):925-37. DOI: 10.1088/0967-3334/24/4/009. View

4.
Allen J . Photoplethysmography and its application in clinical physiological measurement. Physiol Meas. 2007; 28(3):R1-39. DOI: 10.1088/0967-3334/28/3/R01. View

5.
Nilsson L, Goscinski T, Kalman S, Lindberg L, Johansson A . Combined photoplethysmographic monitoring of respiration rate and pulse: a comparison between different measurement sites in spontaneously breathing subjects. Acta Anaesthesiol Scand. 2007; 51(9):1250-7. DOI: 10.1111/j.1399-6576.2007.01375.x. View