» Articles » PMID: 39040071

SolunumWear: A Smart Textile System for Dynamic Respiration Monitoring Across Various Postures

Overview
Journal iScience
Publisher Cell Press
Date 2024 Jul 23
PMID 39040071
Authors
Affiliations
Soon will be listed here.
Abstract

We introduce SolunumWear, a multi-sensory e-textile system designed for respiration in daily life settings, addressing the gap in continuous, real-world respiration event monitoring. Leveraging a textile pressure sensor belt to capture chest movements and a wireless data acquisition system, SolunumWear offers a promising solution for both medical and wellness applications. The system's efficacy was evaluated through a human study involving 10 healthy adults (six female and four male) across various breathing rates and postures, demonstrating a strong correlation (R value = 0.836) with the gold-standard system. The study highlights the system's computational and communication efficiencies, with latencies of approximately 4.84 s and 2.13 ms, respectively. These findings highlight the efficacy of SolunumWear as a wireless, wearable technology for respiration monitoring in daily settings. This research contributes to the expanding body of knowledge on smart textile-based health monitoring technologies, demonstrating its potential to provide reliable respiratory data in real-world environments.

Citing Articles

A Cost-Effective and Easy-to-Fabricate Conductive Velcro Dry Electrode for Durable and High-Performance Biopotential Acquisition.

Guo J, Wang X, Bai R, Zhang Z, Chen H, Xue K Biosensors (Basel). 2024; 14(9).

PMID: 39329808 PMC: 11430566. DOI: 10.3390/bios14090432.

References
1.
Chu M, Nguyen T, Pandey V, Zhou Y, Pham H, Bar-Yoseph R . Respiration rate and volume measurements using wearable strain sensors. NPJ Digit Med. 2019; 2:8. PMC: 6550208. DOI: 10.1038/s41746-019-0083-3. View

2.
Longmore S, Lui G, Naik G, Breen P, Jalaludin B, Gargiulo G . A Comparison of Reflective Photoplethysmography for Detection of Heart Rate, Blood Oxygen Saturation, and Respiration Rate at Various Anatomical Locations. Sensors (Basel). 2019; 19(8). PMC: 6514840. DOI: 10.3390/s19081874. View

3.
Liu X, Wang Q, Liu D, Wang Y, Zhang Y, Bai O . Human emotion classification based on multiple physiological signals by wearable system. Technol Health Care. 2018; 26(S1):459-469. PMC: 6004961. DOI: 10.3233/THC-174747. View

4.
Wertheim D, Olden C, Savage E, Seddon P . Extracting respiratory data from pulse oximeter plethysmogram traces in newborn infants. Arch Dis Child Fetal Neonatal Ed. 2008; 94(4):F301-3. DOI: 10.1136/adc.2008.145342. View

5.
Mayer O, Clayton Sr R, Jawad A, McDonough J, Allen J . Respiratory inductance plethysmography in healthy 3- to 5-year-old children. Chest. 2003; 124(5):1812-9. DOI: 10.1378/chest.124.5.1812. View