» Articles » PMID: 39685975

A Review on Assisted Living Using Wearable Devices

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2024 Dec 17
PMID 39685975
Authors
Affiliations
Soon will be listed here.
Abstract

Forecasts about the aging trend of the world population agree on identifying increased life expectancy as a serious risk factor for the financial sustainability of social healthcare systems if not properly supported by innovative care management policies. Such policies should include the integration within traditional healthcare services of assistive technologies as tools for prolonging healthy and independent living at home, but also for introducing innovations in clinical practice such as long-term and remote health monitoring. For their part, solutions for active and assisted living have now reached a high degree of technological maturity, thanks to the considerable amount of research work carried out in recent years to develop highly reliable and energy-efficient wearable sensors capable of enabling the development of systems to monitor activity and physiological parameters over time, and in a minimally invasive manner. This work reviews the role of wearable sensors in the design and development of assisted living solutions, focusing on human activity recognition by joint use of onboard electromyography sensors and inertial measurement units and on the acquisition of parameters related to overall physical and psychological conditions, such as heart activity and skin conductance.

Citing Articles

High-Accuracy Clock Synchronization in Low-Power Wireless sEMG Sensors.

Biagetti G, Sulis M, Falaschetti L, Crippa P Sensors (Basel). 2025; 25(3).

PMID: 39943395 PMC: 11821185. DOI: 10.3390/s25030756.

References
1.
Sim D, Kim S, Kim S, Doh I . Portable Skin Analyzers with Simultaneous Measurements of Transepidermal Water Loss, Skin Conductance and Skin Hardness. Sensors (Basel). 2019; 19(18). PMC: 6767198. DOI: 10.3390/s19183857. View

2.
Di Giminiani R, Cardinale M, Ferrari M, Quaresima V . Validation of Fabric-Based Thigh-Wearable EMG Sensors and Oximetry for Monitoring Quadriceps Activity during Strength and Endurance Exercises. Sensors (Basel). 2020; 20(17). PMC: 7506815. DOI: 10.3390/s20174664. View

3.
De Luca C, Gilmore L, Kuznetsov M, Roy S . Filtering the surface EMG signal: Movement artifact and baseline noise contamination. J Biomech. 2010; 43(8):1573-9. DOI: 10.1016/j.jbiomech.2010.01.027. View

4.
Mannini A, Rosenberger M, Haskell W, Sabatini A, Intille S . Activity Recognition in Youth Using Single Accelerometer Placed at Wrist or Ankle. Med Sci Sports Exerc. 2016; 49(4):801-812. PMC: 5850929. DOI: 10.1249/MSS.0000000000001144. View

5.
Kim B, Yoo S . Motion artifact reduction in photoplethysmography using independent component analysis. IEEE Trans Biomed Eng. 2006; 53(3):566-8. DOI: 10.1109/TBME.2005.869784. View