Robust Respiration Detection from Remote Photoplethysmography

Overview
Specialty Radiology
Date 2016 Dec 27
PMID 28018717
Citations 23
Authors
Affiliations
Soon will be listed here.
Abstract

Continuous monitoring of respiration is essential for early detection of critical illness. Current methods require sensors attached to the body and/or are not robust to subject motion. Alternative camera-based solutions have been presented using motion vectors and remote photoplethysmography. In this work, we present a non-contact camera-based method to detect respiration, which can operate in both visible and dark lighting conditions by detecting the respiratory-induced colour differences of the skin. We make use of the close similarity between skin colour variations caused by the beating of the heart and those caused by respiration, leading to a much improved signal quality compared to single-channel approaches. Essentially, we propose to find the linear combination of colour channels which suppresses the distortions best in a frequency band including pulse rate, and subsequently we use this same linear combination to extract the respiratory signal in a lower frequency band. Evaluation results obtained from recordings on healthy subjects which perform challenging scenarios, including motion, show that respiration can be accurately detected over the entire range of respiratory frequencies, with a correlation coefficient of 0.96 in visible light and 0.98 in infrared, compared to 0.86 with the best-performing non-contact benchmark algorithm. Furthermore, evaluation on a set of videos recorded in a Neonatal Intensive Care Unit (NICU) shows that this technique looks promising as a future alternative to current contact-sensors showing a correlation coefficient of 0.87.

Citing Articles

Smart Recognition COVID-19 System to Predict Suspicious Persons Based on Face Features.

Ben Ayed M, Massaoudi A, Alshaya S J Electr Eng Technol. 2024; 16(3):1601-1606.

PMID: 38624711 PMC: 7883761. DOI: 10.1007/s42835-021-00671-2.


Clinical applications of contactless photoplethysmography for vital signs monitoring in pediatrics: A systematic review and meta-analysis.

Bautista M, Cave D, Downey C, Bentham J, Jayne D J Clin Transl Sci. 2023; 7(1):e144.

PMID: 37396820 PMC: 10310860. DOI: 10.1017/cts.2023.557.


Contactless SpO with an RGB camera: experimental proof of calibrated SpO.

van Gastel M, Verkruysse W Biomed Opt Express. 2023; 13(12):6791-6802.

PMID: 36589571 PMC: 9774849. DOI: 10.1364/BOE.471332.


Non-contact respiratory rate monitoring using thermal and visible imaging: a pilot study on neonates.

Maurya L, Zwiggelaar R, Chawla D, Mahapatra P J Clin Monit Comput. 2022; 37(3):815-828.

PMID: 36463541 PMC: 10175339. DOI: 10.1007/s10877-022-00945-8.


Multitask Siamese Network for Remote Photoplethysmography and Respiration Estimation.

Lee H, Lee J, Kwon Y, Kwon J, Park S, Sohn R Sensors (Basel). 2022; 22(14).

PMID: 35890781 PMC: 9321619. DOI: 10.3390/s22145101.


References
1.
Poh M, McDuff D, Picard R . Advancements in noncontact, multiparameter physiological measurements using a webcam. IEEE Trans Biomed Eng. 2010; 58(1):7-11. DOI: 10.1109/TBME.2010.2086456. View

2.
Nilsson L . Respiration signals from photoplethysmography. Anesth Analg. 2013; 117(4):859-865. DOI: 10.1213/ANE.0b013e31828098b2. View

3.
van Gastel M, Stuijk S, de Haan G . Motion Robust Remote-PPG in Infrared. IEEE Trans Biomed Eng. 2015; 62(5):1425-33. DOI: 10.1109/TBME.2015.2390261. View

4.
Seymour C, Kahn J, Cooke C, Watkins T, Heckbert S, Rea T . Prediction of critical illness during out-of-hospital emergency care. JAMA. 2010; 304(7):747-54. PMC: 3949007. DOI: 10.1001/jama.2010.1140. View

5.
Al-Khalidi F, Saatchi R, Burke D, Elphick H, Tan S . Respiration rate monitoring methods: a review. Pediatr Pulmonol. 2011; 46(6):523-9. DOI: 10.1002/ppul.21416. View