» Articles » PMID: 28073029

Multiplexed Efficient On-chip Sample Preparation and Sensitive Amplification-free Detection of Ebola Virus

Overview
Date 2017 Jan 11
PMID 28073029
Citations 41
Authors
Affiliations
Soon will be listed here.
Abstract

An automated microfluidic sample preparation multiplexer (SPM) has been developed and evaluated for Ebola virus detection. Metered air bubbles controlled by microvalves are used to improve bead-solution mixing thereby enhancing the hybridization of the target Ebola virus RNA with capture probes bound to the beads. The method uses thermally stable 4-formyl benzamide functionalized (4FB) magnetic beads rather than streptavidin coated beads with a high density of capture probes to improve the target capture efficiency. Exploiting an on-chip concentration protocol in the SPM and the single molecule detection capability of the antiresonant reflecting optical waveguide (ARROW) biosensor chip, a detection limit of 0.021pfu/mL for clinical samples is achieved without target amplification. This RNA target capture efficiency is two orders of magnitude higher than previous results using streptavidin beads and the limit of detection (LOD) improves 10×. The wide dynamic range of this technique covers the whole clinically applicable concentration range. In addition, the current sample preparation time is ~1h which is eight times faster than previous work. This multiplexed, miniaturized sample preparation microdevice establishes a key technology that intended to develop next generation point-of-care (POC) detection system.

Citing Articles

Advances in Nucleic Acid Assays for Infectious Disease: The Role of Microfluidic Technology.

Wang Y, Chen J, Yang Z, Wang X, Zhang Y, Chen M Molecules. 2024; 29(11).

PMID: 38893293 PMC: 11173870. DOI: 10.3390/molecules29112417.


Label-free and amplification-free viral RNA quantification from primate biofluids using a trapping-assisted optofluidic nanopore platform.

Sampad M, Saiduzzaman S, Walker Z, Wells T, Wayment J, Ong E Proc Natl Acad Sci U S A. 2024; 121(16):e2400203121.

PMID: 38598338 PMC: 11032468. DOI: 10.1073/pnas.2400203121.


Micropillar enhanced FRET-CRISPR biosensor for nucleic acid detection.

Bao M, Dollery S, Yuqing F, Tobin G, Du K Lab Chip. 2023; 24(1):47-55.

PMID: 38019145 PMC: 11221459. DOI: 10.1039/d3lc00780d.


Chemical Trends in Sample Preparation for Nucleic Acid Amplification Testing (NAAT): A Review.

Lee S, Kalathil Balakrishnan H, Doeven E, Yuan D, Guijt R Biosensors (Basel). 2023; 13(11).

PMID: 37998155 PMC: 10669371. DOI: 10.3390/bios13110980.


Comparison of Illumination Methods for Flow-Through Optofluidic Biosensors.

Hamblin M, Wright J, Schmidt H, Hawkins A Micromachines (Basel). 2023; 14(4).

PMID: 37420956 PMC: 10142587. DOI: 10.3390/mi14040723.


References
1.
Jackman J, Linardy E, Yoo D, Seo J, Ng W, Klemme D . Plasmonic Nanohole Sensor for Capturing Single Virus-Like Particles toward Virucidal Drug Evaluation. Small. 2015; 12(9):1159-66. DOI: 10.1002/smll.201501914. View

2.
Towner J, Rollin P, Bausch D, Sanchez A, Crary S, Vincent M . Rapid diagnosis of Ebola hemorrhagic fever by reverse transcription-PCR in an outbreak setting and assessment of patient viral load as a predictor of outcome. J Virol. 2004; 78(8):4330-41. PMC: 374287. DOI: 10.1128/jvi.78.8.4330-4341.2004. View

3.
Frommelt T, Kostur M, Wenzel-Schafer M, Talkner P, Hanggi P, Wixforth A . Microfluidic mixing via acoustically driven chaotic advection. Phys Rev Lett. 2008; 100(3):034502. DOI: 10.1103/PhysRevLett.100.034502. View

4.
Thompson B, Ouyang Y, Duarte G, Carrilho E, Krauss S, Landers J . Inexpensive, rapid prototyping of microfluidic devices using overhead transparencies and a laser print, cut and laminate fabrication method. Nat Protoc. 2015; 10(6):875-86. DOI: 10.1038/nprot.2015.051. View

5.
Klamp T, Camps M, Nieto B, Guasch F, Ranasinghe R, Wiedemann J . Highly rapid amplification-free and quantitative DNA imaging assay. Sci Rep. 2013; 3:1852. PMC: 3655336. DOI: 10.1038/srep01852. View