Central X-ray Beam Correction of Radiographic Acetabular Cup Measurement After THA: an Experimental Study

Overview
Publisher Springer
Date 2016 Oct 8
PMID 27714567
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Accurate assessment of cup orientation on postoperative radiographs is essential for evaluating outcome after THA. However, accuracy is impeded by the deviation of the central X-ray beam in relation to the cup and the impossibility of measuring retroversion on standard pelvic radiographs.

Method: In an experimental trial, we built an artificial cup holder enabling the setting of different angles of anatomical anteversion and inclination. Twelve different cup orientations were investigated by three examiners. After comparing the two methods for radiographic measurement of the cup position developed by Lewinnek and Widmer, we showed how to differentiate between anteversion and retroversion in each cup position by using a second plane. To show the effect of the central beam offset on the cup, we X-rayed a defined cup position using a multidirectional central beam offset. According to Murray's definition of anteversion and inclination, we created a novel corrective procedure to balance measurement errors caused by deviation of the central beam.

Results: Measurement of the 12 different cup positions with the Lewinnek's method yielded a mean deviation of [Formula: see text] (95 % CI 1.3-2.3) from the original cup anteversion. The respective deviation with the Widmer/Liaw's method was [Formula: see text] (95 % CI 2.4-4.0). In each case, retroversion could be differentiated from anteversion with a second radiograph. Because of the multidirectional central beam offset ([Formula: see text] cm) from the acetabular cup in the cup holder ([Formula: see text] anteversion and [Formula: see text] inclination), the mean absolute difference for anteversion was [Formula: see text] (range [Formula: see text] to [Formula: see text] and [Formula: see text] (range [Formula: see text] to [Formula: see text] for inclination. The application of our novel mathematical correction of the central beam offset reduced deviation to a mean difference of [Formula: see text] for anteversion and [Formula: see text] for inclination.

Conclusion: This novel calculation for central beam offset correction enables highly accurate measurement of the cup position.

Citing Articles

Three-dimensional acetabular reorientation during periacetabular osteotomy: an intraoperative navigation method using an external fixator for periacetabular osteotomy.

Schwarz T, Maderbacher G, Leiss F, Grifka J, Kappenschneider T, Knebl M Arch Orthop Trauma Surg. 2024; 144(11):4969-4977.

PMID: 39313642 DOI: 10.1007/s00402-024-05590-1.


Polyethylene liner dissociation in total hip arthroplasty: a retrospective case-control study on a single implant design.

Pagano S, Plate J, Kappenschneider T, Reinhard J, Scharf M, Maderbacher G J Orthop Traumatol. 2024; 25(1):38.

PMID: 39143399 PMC: 11324622. DOI: 10.1186/s10195-024-00785-z.


Reliability and accuracy of intraoperative fluoroscopy assessment of acetabular cup anteversion in supine direct anterior approach total hip arthroplasty.

Li W, Huang Y, Zou Z, Liu X, Li X Sci Rep. 2024; 14(1):12469.

PMID: 38816424 PMC: 11139957. DOI: 10.1038/s41598-024-62964-6.


How Relevant Is the Parallax Effect on Low Centered Pelvic Radiographs in Total Hip Arthroplasty.

Weber M, Meyer M, von Kunow F, Fuchtmeier B, Hillmann A, Wulbrand C J Pers Med. 2023; 13(6).

PMID: 37373870 PMC: 10302827. DOI: 10.3390/jpm13060881.


Achieving Precise Cup Positioning in Direct Anterior Total Hip Arthroplasty: A Narrative Review.

Streck L, Boettner F Medicina (Kaunas). 2023; 59(2).

PMID: 36837472 PMC: 9959722. DOI: 10.3390/medicina59020271.


References
1.
Marx A, von Knoch M, Pfortner J, Wiese M, Saxler G . Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography. Arch Orthop Trauma Surg. 2006; 126(7):487-92. DOI: 10.1007/s00402-006-0163-0. View

2.
Lewinnek G, Lewis J, Tarr R, COMPERE C, Zimmerman J . Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978; 60(2):217-20. View

3.
Patil S, Bergula A, Chen P, Colwell Jr C, DLima D . Polyethylene wear and acetabular component orientation. J Bone Joint Surg Am. 2003; 85-A Suppl 4:56-63. DOI: 10.2106/00004623-200300004-00007. View

4.
Craiovan B, Renkawitz T, Weber M, Grifka J, Nolte L, Zheng G . Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate?. Int Orthop. 2014; 38(10):2009-15. DOI: 10.1007/s00264-014-2336-8. View

5.
Lu M, Zhou Y, Du H, Zhang J, Liu J . Reliability and validity of measuring acetabular component orientation by plain anteroposterior radiographs. Clin Orthop Relat Res. 2013; 471(9):2987-94. PMC: 3734435. DOI: 10.1007/s11999-013-3021-8. View