Dislocations After Total Hip-replacement Arthroplasties

Overview
Date 1978 Mar 1
PMID 641088
Citations 854
Authors
Affiliations
Soon will be listed here.
Abstract

In a series of 300 total hip replacements, nine (3 per cent) dislocated. Precise measurements of the orientation of the acetabular cup were made and it was found that anterior dislocations were associated with increased acetabular-component anteversion. There was no significant correlation between cup-orientation angle and posterior dislocation. The dislocation rate for cup orientation with anteversion of 15 +/- 10 degrees and lateral opening of 40 +/- 10 degrees was 1.5 per cent, while outside this "safe" range the dislocation rate was 6.1 per cent. Other factors that were documented include time after surgery (with the greatest risk in the first thirty days) and surgical history (with a greater risk in hips that have had prior surgery).

Citing Articles

Evaluation of cup placement accuracy in computer assisted total hip arthroplasty.

Kaneta H, Shoji T, Ueki S, Morita H, Kozuma Y, Adachi N Arch Orthop Trauma Surg. 2025; 145(1):191.

PMID: 40085242 DOI: 10.1007/s00402-025-05797-w.


Application and exploration of total hip arthroplasty for developmental dysplasia of the hip assisted by full-process robotics.

Shi H, Yu R, Pu L, Qi B, Meng C, Ren J BMC Musculoskelet Disord. 2025; 26(1):225.

PMID: 40050806 PMC: 11884115. DOI: 10.1186/s12891-025-08460-y.


High Risk of Revision Associated with the L-Cup Titanium Alloy Porous Coated Acetabular Component in Primary Total Hip Arthroplasty: Minimum Follow-Up of 14 Years.

Drobniewski M, Ruzik K, Gonera B, Olewnik L, Borowski A, Triantafyllou G J Clin Med. 2025; 14(4).

PMID: 40004831 PMC: 11857016. DOI: 10.3390/jcm14041301.


Use of augmented reality surgical navigation reduces intraoperative fluoroscopic imaging in anterior total hip arthroplasty with equivalent accuracy for component positioning.

Coden G, Kuznetsov M, Schoeller L, Patti J, Grant A, Miller J J Orthop. 2025; 68:15-19.

PMID: 39991507 PMC: 11840186. DOI: 10.1016/j.jor.2025.01.031.


A Handheld, Portable Image-Based System May Outperform Computer Navigation or Robotic Platforms in Providing Accurate Acetabular Component Positioning.

Slotkin E, Coxe F, Jones T, Morton T, Kreutzer S, Della Valle A Arthroplast Today. 2025; 30:101511.

PMID: 39959380 PMC: 11827077. DOI: 10.1016/j.artd.2024.101511.