Measurement of the Acetabular Cup Anteversion on Simulated Radiographs

Overview
Journal J Arthroplasty
Specialty Orthopedics
Date 2008 Jun 7
PMID 18534457
Citations 24
Authors
Affiliations
Soon will be listed here.
Abstract

Widmer (J Arthroplasty 2004;19:387) reported a protractor for measuring the anteversion of acetabular cups on radiographs but with limited precision. We intended to improve its precision by trigonometric mathematics. We measured the anteversion of the acetabular cups on 336 simulated radiographs using aforementioned 2 methods. The anteversion measured by Widmer's protractor ranged from 7 degrees to 41 degrees (mean +/- SD = 28.0 degrees +/- 9.8 degrees), and our methods, 5 degrees to 51 degrees (27.7 degrees +/- 13.2 degrees). The mean +/- SD of error by Widmer's protractor was 5.2 +/- 2.5 degrees, and our protractor, 0.8 degrees +/- 0.8 degrees (Student t test, P b .0001). The interobserver study showed the difference between measurements less than 2 degrees for each method. Therefore, the smaller error of our method than that of Widmer implicated a potentially precise measurement of the anteversion (level of evidence: diagnostic study, level II).

Citing Articles

Automated Web Tool Measurement of Total Hip Arthroplasty Acetabular Component Inclination and Anteversion Angles.

Yoon C, Eligulashvili A, Seref-Ferlengez Z, Goker B, Kamara E, Mardakhaev E Arthroplast Today. 2025; 31():101606.

PMID: 39872119 PMC: 11770501. DOI: 10.1016/j.artd.2024.101606.


Assessing the Reliability of Postoperative Cross-Table Radiographs Compared to CT Scans for Measuring Acetabular Anteversion Angle Following Total Hip Arthroplasty.

Kaushik A, Kumar C V, Hegde A, Mathias L, Shetty V Cureus. 2024; 16(9):e68575.

PMID: 39371801 PMC: 11449688. DOI: 10.7759/cureus.68575.


Preserving medial iliofemoral ligament avoids excessive leg lengthening in total hip arthroplasty using anterolateral-supine approach.

Kurishima H, Yamada N, Noro A, Tanaka H, Takahashi S, Tsuchida K J Orthop. 2024; 60:29-34.

PMID: 39345678 PMC: 11437599. DOI: 10.1016/j.jor.2024.09.004.


Correlation of Acetabular Cup Placement Angles Between an Artificial Intelligence-Powered System Using a Smartphone and Human Measurements.

Tsukada S, Ogawa H, Saito M, Hirasawa N Arthroplast Today. 2024; 29:101439.

PMID: 39328881 PMC: 11424794. DOI: 10.1016/j.artd.2024.101439.


Laser projector method for measuring postoperative acetabular anteversion after total hip replacement.

Chen W, Wu T, Chi K, Weng P, Huang Y, Lin Y Front Surg. 2022; 9:1033453.

PMID: 36353614 PMC: 9637855. DOI: 10.3389/fsurg.2022.1033453.