Lewinnek Safe Zone References Are Frequently Misquoted

Overview
Publisher Elsevier
Date 2020 Dec 10
PMID 33299915
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Optimal acetabular component orientation in total hip arthroplasty (THA) is a necessity in achieving a stable implant. Although there has been considerable debate in the literature concerning the safe zone, to date, there has not been any review to determine if these references are consistent with the definition applied by Lewinnek et al. in 1978. Therefore, this article aims to examine the available literature in the PubMed database to determine how often a correct reference to the safe zone as defined by Lewinnek was applied to discussions regarding THA.

Methods: A search for literature in the PubMed database was performed for articles from 1978 to 2019. Search criteria included terms 'Lewinnek,' 'safe zone,' and 'total hip arthroplasty.' Exclusions included abstract-only articles, non-English articles, articles unrelated to THA, and those lacking full content.

Results: A review of literature yielded 147 articles for inclusion. Overall, only 11% (17) cited the Lewinnek article correctly. Forty-five percent (66) of articles referenced measurements in the supine position, 18% (26) referenced other positions, and 37% (55) did not specify. Nineteen percent (28) reported measurements of the acetabular cup orthogonal to the anterior pelvic plane, while 73% (108) did not, and 7% (11) did not specify. Twenty-three percent (34) measured from computed tomography scans instead of other methods.

Conclusions: In the discussion of the safe zone regarding THA, only 11% of articles listed are consistent with the definition established by Lewinnek. This warrants further investigation into a consistent application of the term and its implications for THA implant stability and dislocation rates.

Citing Articles

Polyethylene liner dissociation in total hip arthroplasty: a retrospective case-control study on a single implant design.

Pagano S, Plate J, Kappenschneider T, Reinhard J, Scharf M, Maderbacher G J Orthop Traumatol. 2024; 25(1):38.

PMID: 39143399 PMC: 11324622. DOI: 10.1186/s10195-024-00785-z.


Radiographic study of direct anterior approach hip arthroplasty: a 10-15 year follow-up of Chinese patients.

Sang W, Lai P, Xu X, Liu Y, Ma J, Zhu L Arthroplasty. 2024; 6(1):25.

PMID: 38698494 PMC: 11067169. DOI: 10.1186/s42836-024-00249-z.


Association between sagittal spinal alignment and mechanical complications after primary total hip arthroplasty: a systematic review.

Susanna H, Jussi R, Teemu K, Kati K J Int Med Res. 2022; 50(8):3000605221116976.

PMID: 35971315 PMC: 9386850. DOI: 10.1177/03000605221116976.

References
1.
Trieu J, Hadden A, Sutherland A . Assessment of acetabular version in total hip arthroplasty: an application of Widmer's technique in a regional setting. ANZ J Surg. 2018; 88(6):573-576. DOI: 10.1111/ans.14506. View

2.
Nomura T, Naito M, Nakamura Y, Ida T, Kuroda D, Kobayashi T . An analysis of the best method for evaluating anteversion of the acetabular component after total hip replacement on plain radiographs. Bone Joint J. 2014; 96-B(5):597-603. DOI: 10.1302/0301-620X.96B.33013. View

3.
Davda K, Smyth N, Cobb J, Hart A . 2D measurements of cup orientation are less reliable than 3D measurements. Acta Orthop. 2015; 86(4):485-90. PMC: 4513605. DOI: 10.3109/17453674.2015.1017791. View

4.
M Ecker T, Tannast M, Murphy S . Computed tomography-based surgical navigation for hip arthroplasty. Clin Orthop Relat Res. 2007; 465:100-5. DOI: 10.1097/BLO.0b013e3181591c7d. View

5.
Rojas J, Bautista M, Bonilla G, Amado O, Huerfano E, Monsalvo D . A retrospective study on the relationship between altered native acetabular angle and vertical implant malpositioning. Int Orthop. 2017; 42(4):769-775. DOI: 10.1007/s00264-017-3584-1. View