» Articles » PMID: 24585403

Quantification of Liver Iron with MRI: State of the Art and Remaining Challenges

Overview
Date 2014 Mar 4
PMID 24585403
Citations 125
Authors
Affiliations
Soon will be listed here.
Abstract

Liver iron overload is the histological hallmark of hereditary hemochromatosis and transfusional hemosiderosis, and can also occur in chronic hepatopathies. Iron overload can result in liver damage, with the eventual development of cirrhosis, liver failure, and hepatocellular carcinoma. Assessment of liver iron levels is necessary for detection and quantitative staging of iron overload and monitoring of iron-reducing treatments. This article discusses the need for noninvasive assessment of liver iron and reviews qualitative and quantitative methods with a particular emphasis on magnetic resonance imaging (MRI). Specific MRI methods for liver iron quantification include signal intensity ratio as well as R2 and R2* relaxometry techniques. Methods that are in clinical use, as well as their limitations, are described. Remaining challenges, unsolved problems, and emerging techniques to provide improved characterization of liver iron deposition are discussed.

Citing Articles

Reproducibility of liver iron concentration measured by R2* method based on 1.5-T MRI: a meta-analysis.

Cao S, Zhang J, Dong C, Que Y, Gao X, Guo R Eur Radiol. 2025; .

PMID: 39751630 DOI: 10.1007/s00330-024-11334-x.


Computed Tomography and Magnetic Resonance Imaging in Liver Iron Overload: From Precise Quantification to Prognosis Assessment.

Zhou X, Jia X, Chen Y, Song B Biomedicines. 2024; 12(11).

PMID: 39595022 PMC: 11592092. DOI: 10.3390/biomedicines12112456.


Assessing the accuracy of CMRtools software for diagnosing liver iron overload in thalassemia patients: influencing factors and optimisation strategies.

Luo C, Peng F, Xu F, Tang C, Zhang Y, Huang C Front Med (Lausanne). 2024; 11:1424294.

PMID: 39371340 PMC: 11449772. DOI: 10.3389/fmed.2024.1424294.


Simultaneous Multiparameter Mapping of the Liver in a Single Breath-Hold or Respiratory-Triggered Acquisition Using Multi-Inversion Spin and Gradient Echo MRI.

Manhard M, Kilpattu Ramaniharan A, Tkach J, Trout A, Dillman J, Pednekar A J Magn Reson Imaging. 2024; 61(4):1925-1936.

PMID: 39192381 PMC: 11896940. DOI: 10.1002/jmri.29584.


Application and research progress of magnetic resonance proton density fat fraction in metabolic dysfunction-associated steatotic liver disease: a comprehensive review.

Qi H, Jiang S, Nan J, Guo H, Cheng C, He X Abdom Radiol (NY). 2024; 50(1):185-197.

PMID: 39048719 DOI: 10.1007/s00261-024-04448-9.


References
1.
Leitch H . Controversies surrounding iron chelation therapy for MDS. Blood Rev. 2010; 25(1):17-31. DOI: 10.1016/j.blre.2010.09.003. View

2.
Papakonstantinou O, Foufa K, Benekos O, Alexopoulou E, Mademli M, Balanika A . Use of fat suppression in R₂ relaxometry with MRI for the quantification of tissue iron overload in beta-thalassemic patients. Magn Reson Imaging. 2012; 30(7):926-33. DOI: 10.1016/j.mri.2012.03.002. View

3.
Bydder G, STEINER R, Blumgart L, Khenia S, Young I . MR imaging of the liver using short TI inversion recovery sequences. J Comput Assist Tomogr. 1985; 9(6):1084-9. DOI: 10.1097/00004728-198511000-00015. View

4.
Pavitt H, Aydinok Y, El-Beshlawy A, Bayraktaroglu S, Ibrahim A, Hamdy M . The effect of reducing repetition time TR on the measurement of liver R2 for the purpose of measuring liver iron concentration. Magn Reson Med. 2011; 65(5):1346-51. DOI: 10.1002/mrm.22712. View

5.
Bravo A, Sheth S, Chopra S . Liver biopsy. N Engl J Med. 2001; 344(7):495-500. DOI: 10.1056/NEJM200102153440706. View