Shao X, Zhang Z, Ma X, Liu F, Guo H, Ugurbil K
Magn Reson Med. 2024; 93(3):1238-1255.
PMID: 39481025
PMC: 11682926.
DOI: 10.1002/mrm.30346.
Wang Y, Qi H, Wang Y, Xiao M, Xiang C, Dong J
Quant Imaging Med Surg. 2023; 13(2):912-923.
PMID: 36819282
PMC: 9929423.
DOI: 10.21037/qims-22-748.
Meloni A, Positano V, Pistoia L, Cademartiri F
Abdom Radiol (NY). 2022; 47(7):2397-2407.
PMID: 35596775
DOI: 10.1007/s00261-022-03552-y.
Santarelli M, Meloni A, De Marchi D, Pistoia L, Quarta A, Spasiano A
MAGMA. 2018; 31(6):757-769.
PMID: 30043125
DOI: 10.1007/s10334-018-0695-7.
Stinson E, Trzasko J, Campeau N, Glockner J, Huston 3rd J, Young P
Magn Reson Med. 2018; 80(4):1556-1567.
PMID: 29488251
PMC: 6097950.
DOI: 10.1002/mrm.27152.
Optimal Fat Suppression in Head and Neck MRI: Comparison of Multipoint Dixon with 2 Different Fat-Suppression Techniques, Spectral Presaturation and Inversion Recovery, and STIR.
Gaddikeri S, Mossa-Basha M, Andre J, Hippe D, Anzai Y
AJNR Am J Neuroradiol. 2017; 39(2):362-368.
PMID: 29242364
PMC: 7410601.
DOI: 10.3174/ajnr.A5483.
Advancing imaging technologies for patients with spinal pain: with a focus on whiplash injury.
Elliott J, Hancock M, Crawford R, Smith A, Walton D
Spine J. 2017; 18(8):1489-1497.
PMID: 28774580
PMC: 6874915.
DOI: 10.1016/j.spinee.2017.06.015.
Renal Adiposity Confounds Quantitative Assessment of Markers of Renal Diffusion With MRI: A Proposed Correction Method.
Ebrahimi B, Saad A, Jiang K, Ferguson C, Tang H, Woollard J
Invest Radiol. 2017; 52(11):672-679.
PMID: 28562413
PMC: 5633488.
DOI: 10.1097/RLI.0000000000000389.
Magnetic resonance imaging of the spinal marrow: Basic understanding of the normal marrow pattern and its variant.
Nouh M, Eid A
World J Radiol. 2016; 7(12):448-58.
PMID: 26753060
PMC: 4697119.
DOI: 10.4329/wjr.v7.i12.448.
Dixon-type and subtraction-type contrast-enhanced magnetic resonance angiography: A theoretical and experimental comparison of SNR and CNR.
Stinson E, Trzasko J, Weavers P, Riederer S
Magn Reson Med. 2014; 74(1):81-92.
PMID: 25043453
PMC: 4298483.
DOI: 10.1002/mrm.25374.
Fat water decomposition using globally optimal surface estimation (GOOSE) algorithm.
Cui C, Wu X, Newell J, Jacob M
Magn Reson Med. 2014; 73(3):1289-99.
PMID: 24604689
PMC: 4411245.
DOI: 10.1002/mrm.25193.
Improving chemical shift encoded water-fat separation using object-based information of the magnetic field inhomogeneity.
Sharma S, Artz N, Hernando D, Horng D, Reeder S
Magn Reson Med. 2014; 73(2):597-604.
PMID: 24585487
PMC: 4148476.
DOI: 10.1002/mrm.25163.
Quantification of liver iron with MRI: state of the art and remaining challenges.
Hernando D, Levin Y, Sirlin C, Reeder S
J Magn Reson Imaging. 2014; 40(5):1003-21.
PMID: 24585403
PMC: 4308740.
DOI: 10.1002/jmri.24584.
Quantification of cervical spine muscle fat: a comparison between T1-weighted and multi-echo gradient echo imaging using a variable projection algorithm (VARPRO).
Elliott J, Walton D, Rademaker A, Parrish T
BMC Med Imaging. 2013; 13:30.
PMID: 24020963
PMC: 3847132.
DOI: 10.1186/1471-2342-13-30.
Multipeak fat-corrected complex R2* relaxometry: theory, optimization, and clinical validation.
Hernando D, Kramer J, Reeder S
Magn Reson Med. 2013; 70(5):1319-31.
PMID: 23359327
PMC: 3893831.
DOI: 10.1002/mrm.24593.
Magnetic resonance imaging of ankle tendon pathology: benefits of additional axial short-tau inversion recovery imaging to reduce magic angle effects.
Srikhum W, Nardo L, Karampinos D, Melkus G, Poulos T, Steinbach L
Skeletal Radiol. 2012; 42(4):499-510.
PMID: 23229628
DOI: 10.1007/s00256-012-1550-y.
R2* estimation using "in-phase" echoes in the presence of fat: the effects of complex spectrum of fat.
Hernando D, Kuhn J, Mensel B, Volzke H, Puls R, Hosten N
J Magn Reson Imaging. 2012; 37(3):717-26.
PMID: 23055408
PMC: 3578028.
DOI: 10.1002/jmri.23851.
Practical application of iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) imaging in minimizing metallic artifacts.
Cha J, Hong H, Soung Park J, Paik S, Lee H
Korean J Radiol. 2012; 13(3):332-41.
PMID: 22563271
PMC: 3337870.
DOI: 10.3348/kjr.2012.13.3.332.
R*(2) mapping in the presence of macroscopic B₀ field variations.
Hernando D, Vigen K, Shimakawa A, Reeder S
Magn Reson Med. 2011; 68(3):830-40.
PMID: 22161866
PMC: 3506253.
DOI: 10.1002/mrm.23306.
Removal of olefinic fat chemical shift artifact in diffusion MRI.
Hernando D, Karampinos D, King K, Haldar J, Majumdar S, Georgiadis J
Magn Reson Med. 2011; 65(3):692-701.
PMID: 21337402
PMC: 3069507.
DOI: 10.1002/mrm.22670.