» Articles » PMID: 38872042

Reproducibility and Repeatability of Quantitative T2 and T2* Mapping of Osteosarcomas in a Mouse Model

Overview
Journal Eur Radiol Exp
Date 2024 Jun 13
PMID 38872042
Authors
Affiliations
Soon will be listed here.
Abstract

Background: New immunotherapies activate tumor-associated macrophages (TAMs) in the osteosarcoma microenvironment. Iron oxide nanoparticles (IONPs) are phagocytosed by TAMs and, therefore, enable TAM detection on T2*- and T2-weighted magnetic resonance images. We assessed the repeatability and reproducibility of T2*- and T2-mapping of osteosarcomas in a mouse model.

Methods: Fifteen BALB/c mice bearing-murine osteosarcomas underwent magnetic resonance imaging (MRI) on 3-T and 7-T scanners before and after intravenous IONP infusion, using T2*-weighted multi-gradient-echo, T2-weighted fast spin-echo, and T2-weighted multi-echo sequences. Each sequence was repeated twice. Tumor T2 and T2* relaxation times were measured twice by two independent investigators. Repeatability and reproducibility of measurements were assessed.

Results: We found excellent agreement between duplicate acquisitions for both T2* and T2 measurements at either magnetic field strength, by the same individual (repeatability), and between individuals (reproducibility). The repeatability concordance correlation coefficient (CCC) for T2* values were 0.99 (coefficients of variation (CoV) 4.43%) for reader 1 and 0.98 (CoV 5.82%) for reader 2. The reproducibility of T2* values between the two readers was 0.99 (CoV 3.32%) for the first acquisitions and 0.99 (CoV 6.30%) for the second acquisitions. Regarding T2 values, the repeatability of CCC was similar for both readers, 0.98 (CoV 3.64% for reader 1 and 4.45% for reader 2). The CCC of the reproducibility of T2 was 0.99 (CoV 3.1%) for the first acquisition and 0.98 (CoV 4.38%) for the second acquisition.

Conclusions: Our results demonstrated high repeatability and reproducibility of quantitative T2* and T2 mapping for monitoring the presence of TAMs in osteosarcomas.

Relevance Statement: T2* and T2 measurements of osteosarcomas on IONP-enhanced MRI could allow identifying patients who may benefit from TAM-modulating immunotherapies and for monitoring treatment response. The technique described here could be also applied across a wide range of other solid tumors.

Key Points: • Optimal integration of TAM-modulating immunotherapies with conventional chemotherapy remains poorly elucidated. • We found high repeatability of T2* and T2 measurements of osteosarcomas in a mouse model, both with and without IONPs contrast, at 3-T and 7-T MRI field strengths. • T2 and T2* mapping may be used to determine response to macrophage-modulating cancer immunotherapies.

References
1.
Li S, Liu J, Zhang F, Yang M, Zhang Z, Liu J . Novel T2 Mapping for Evaluating Cervical Cancer Features by Providing Quantitative T2 Maps and Synthetic Morphologic Images: A Preliminary Study. J Magn Reson Imaging. 2020; 52(6):1859-1869. DOI: 10.1002/jmri.27297. View

2.
Tong S, Zhu H, Bao G . Magnetic Iron Oxide Nanoparticles for Disease Detection and Therapy. Mater Today (Kidlington). 2020; 31:86-99. PMC: 7441585. DOI: 10.1016/j.mattod.2019.06.003. View

3.
Mohanty S, Yerneni K, Theruvath J, Graef C, Nejadnik H, Lenkov O . Nanoparticle enhanced MRI can monitor macrophage response to CD47 mAb immunotherapy in osteosarcoma. Cell Death Dis. 2019; 10(2):36. PMC: 6367456. DOI: 10.1038/s41419-018-1285-3. View

4.
Strauss S, Frezza A, Abecassis N, Bajpai J, Bauer S, Biagini R . Bone sarcomas: ESMO-EURACAN-GENTURIS-ERN PaedCan Clinical Practice Guideline for diagnosis, treatment and follow-up. Ann Oncol. 2021; 32(12):1520-1536. DOI: 10.1016/j.annonc.2021.08.1995. View

5.
Koo T, Li M . A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. J Chiropr Med. 2016; 15(2):155-63. PMC: 4913118. DOI: 10.1016/j.jcm.2016.02.012. View