» Articles » PMID: 20596841

Quantification of Myocardial Blood Flow and Flow Reserve: Technical Aspects

Overview
Journal J Nucl Cardiol
Date 2010 Jul 3
PMID 20596841
Citations 57
Authors
Affiliations
Soon will be listed here.
Citing Articles

Inter-Software Reproducibility of Quantitative Values of Myocardial Blood Flow and Coronary Flow Reserve Acquired by [N]NH MPI PET/CT and the Effect of Motion Correction Tools.

Mendoza-Ibanez O, Slart R, Alexanderson-Rosas E, Martinez-Lucio T, van der Zant F, Knol R Diagnostics (Basel). 2025; 15(5).

PMID: 40075861 PMC: 11898590. DOI: 10.3390/diagnostics15050613.


Improved detection of coronary artery disease by CZT regional coronary blood flow evaluation.

Lima R, Bezerra A, Andrade M, Domenico C, De Lorenzo A Front Nucl Med. 2024; 2:1072729.

PMID: 39354966 PMC: 11440858. DOI: 10.3389/fnume.2022.1072729.


Automatic reorientation to generate short-axis myocardial PET images.

Yang Y, Wang F, Han X, Xu H, Zhang Y, Xu W EJNMMI Phys. 2024; 11(1):70.

PMID: 39090442 PMC: 11294504. DOI: 10.1186/s40658-024-00673-9.


Optimization of Tl Dosage in a Simultaneous Acquisition Rest Tc/Stress Tl Dual-Isotope Myocardial Perfusion Single-Photon Emission Computed Tomography with Semiconductor Gamma Camera.

Sugai S, Matsumoto N, Makita A, Kuronuma K, Suzuki Y, Hori Y Ann Nucl Cardiol. 2023; 9(1):68-72.

PMID: 38058585 PMC: 10696141. DOI: 10.17996/anc.23-00010.


SPECT myocardial blood flow quantitation for the detection of angiographic stenoses with cardiac-dedicated CZT SPECT.

Zhang J, Xie J, Li M, Fang W, Hsu B J Nucl Cardiol. 2023; 30(6):2618-2632.

PMID: 37491508 DOI: 10.1007/s12350-023-03334-z.


References
1.
Dayanikli F, Grambow D, Muzik O, Mosca L, Rubenfire M, Schwaiger M . Early detection of abnormal coronary flow reserve in asymptomatic men at high risk for coronary artery disease using positron emission tomography. Circulation. 1994; 90(2):808-17. DOI: 10.1161/01.cir.90.2.808. View

2.
Herrero P, Markham J, Shelton M, Weinheimer C, Bergmann S . Noninvasive quantification of regional myocardial perfusion with rubidium-82 and positron emission tomography. Exploration of a mathematical model. Circulation. 1990; 82(4):1377-86. DOI: 10.1161/01.cir.82.4.1377. View

3.
Klein R, Adler A, Beanlands R, deKemp R . Precision-controlled elution of a 82Sr/82Rb generator for cardiac perfusion imaging with positron emission tomography. Phys Med Biol. 2007; 52(3):659-73. DOI: 10.1088/0031-9155/52/3/009. View

4.
Parkash R, deKemp R, Ruddy T, Kitsikis A, Hart R, Beauchesne L . Potential utility of rubidium 82 PET quantification in patients with 3-vessel coronary artery disease. J Nucl Cardiol. 2004; 11(4):440-9. DOI: 10.1016/j.nuclcard.2004.04.005. View

5.
deKemp R, Ruddy T, Hewitt T, Dalipaj M, Beanlands R . Detection of serial changes in absolute myocardial perfusion with 82Rb PET. J Nucl Med. 2000; 41(8):1426-35. View