» Articles » PMID: 10945537

Detection of Serial Changes in Absolute Myocardial Perfusion with 82Rb PET

Overview
Journal J Nucl Med
Specialty Nuclear Medicine
Date 2000 Aug 17
PMID 10945537
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Unlabelled: Serial changes in myocardial perfusion may represent an important marker of disease progression or regression or the effects of therapy for patients with coronary artery disease (CAD). Quantitative methods have not been developed for the assessment of serial changes in perfusion. The objective of this study was to use receiver operator characteristic (ROC) analysis to determine the sensitivity and specificity of direct paired comparisons (DPCs) to detect changes in absolute myocardial perfusion measured with 82Rb PET.

Methods: Repeated dynamic 82Rb PET scans were obtained on 8 dogs at rest and during hyperemia induced with dobutamine (n = 4) or atrial pacing (n = 4). Radiolabeled microspheres were used to verify perfusion changes. Polar maps of absolute 82Rb retention and associated SD were estimated from the dynamic images. Paired comparisons were then performed using a t test on each of the 532 polar map sectors. Rest-rest and stress-stress differences were used to assess specificity and reproducibility, and stress-rest differences were used to assess sensitivity.

Results: 82Rb retention differences of 20% over baseline were detected with 85%-90% sensitivity and specificity, using the optimal DPC probability value and image smoothness. The average 82Rb retention differences correlated well with microspheres (r = 0.74; P = 0.001). Reproducibility of the mean retention values was 4.7% +/- 2.1%. As reproducibility varies, the DPC probability value can be adjusted to maintain specificity. These ROC results are directly applicable to other image modalities that produce measurements with similar SEs (3.7% +/- 0.9%).

Conclusion: The developed method of DPCs is sensitive and specific for the detection of changes in absolute myocardial perfusion measured with 82Rb PET.

Citing Articles

Development of a dedicated 3D printed myocardial perfusion phantom: proof-of-concept in dynamic SPECT.

Kamphuis M, de Vries G, Kuipers H, Saaltink M, Verschoor J, Greuter M Med Biol Eng Comput. 2022; 60(6):1541-1550.

PMID: 35048275 PMC: 9079041. DOI: 10.1007/s11517-021-02490-z.


Time-frame sampling for Rb PET flow quantification: Towards standardization of clinical protocols.

Klein R, Ocneanu A, deKemp R J Nucl Cardiol. 2017; 24(5):1530-1534.

PMID: 28687966 DOI: 10.1007/s12350-017-0981-1.


Segmental quantitative myocardial perfusion with PET for the detection of significant coronary artery disease in patients with stable angina.

Berti V, Sciagra R, Neglia D, Pietila M, Scholte A, Nekolla S Eur J Nucl Med Mol Imaging. 2016; 43(8):1522-9.

PMID: 26993310 DOI: 10.1007/s00259-016-3362-0.


Serial imaging and outcome prediction.

Iskandrian A, Roth C, Hage F J Nucl Cardiol. 2015; 23(1):117-21.

PMID: 26514576 DOI: 10.1007/s12350-015-0312-3.


It's not all in the numbers.

Travin M J Nucl Cardiol. 2015; 23(3):436-41.

PMID: 25802176 DOI: 10.1007/s12350-015-0105-8.