» Articles » PMID: 39354966

Improved Detection of Coronary Artery Disease by CZT Regional Coronary Blood Flow Evaluation

Overview
Journal Front Nucl Med
Date 2024 Oct 2
PMID 39354966
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: CZT cameras have enabled the noninvasive quantification of myocardial flow reserve (MFR), an important physiologic measure. This study aimed to compare myocardial perfusion SPECT (MPS) with or without MFR evaluation for the detection of obstructive coronary artery disease (CAD).

Methods: 48 patients with CAD (>50% obstruction) detected at invasive coronary angiography or CT angiography underwent dipyridamole MPS and MFR evaluation within 30 days. A 1-day protocol (rest-stress) was used to quantify MFR. The acquisition of dynamic rest and stress images was initiated simultaneously to 99mTc sestamibi injection (370 and 1,110 MBq, respectively), both lasting for 11 min, followed by 5-min imaging. Pharmacologic stress with dipyridamole (0.56 mg/kg for 4 min) was performed with the patient positioned in the CZT camera. The images were processed and time-activity curves were generated, calculating global and regional MFR in a semiautomatic software. A global or regional MFR <2 was considered abnormal. MPS perfusion images were classified as normal or abnormal. The images were interpreted by experienced physicians blinded to the results of MFR and coronary angiography/CT.

Results: Mean age of the population was 61 ± 9 years, 54.2% female. Twenty patients (41.7%) had single-vessel CAD, 22 (45.8%) 2-vessel CAD and 6 (12.5%), triple-vessel CAD. Among the 82 vessels with obstruction, 48 had perfusion abnormalities in MPS and 60 had reduced MFR, while among the normal vessels, had 54 normal MPS and 52 had preserved MFR. The sensitivity of MFR (69%) was higher than that of MPS (55.2%), without significant changes in specificity (86 vs. 83.7%).

Conclusions: MFR in the CZT camera is more sensitive for the detection of CAD than perfusion abnormalities in MPS, especially in patients with multivessel CAD.

References
1.
Gould K, Lipscomb K, Hamilton G . Physiologic basis for assessing critical coronary stenosis. Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve. Am J Cardiol. 1974; 33(1):87-94. DOI: 10.1016/0002-9149(74)90743-7. View

2.
Slomka P, Miller R, Hu L, Germano G, Berman D . Solid-State Detector SPECT Myocardial Perfusion Imaging. J Nucl Med. 2019; 60(9):1194-1204. DOI: 10.2967/jnumed.118.220657. View

3.
Acampa W, Assante R, Mannarino T, Zampella E, DAntonio A, Buongiorno P . Low-dose dynamic myocardial perfusion imaging by CZT-SPECT in the identification of obstructive coronary artery disease. Eur J Nucl Med Mol Imaging. 2019; 47(7):1705-1712. DOI: 10.1007/s00259-019-04644-6. View

4.
Carolina do A H de Souza A, Harms H, Martell L, Bibbo C, Harrington M, Sullivan K . Accuracy and Reproducibility of Myocardial Blood Flow Quantification by Single Photon Emission Computed Tomography Imaging in Patients With Known or Suspected Coronary Artery Disease. Circ Cardiovasc Imaging. 2022; 15(6):e013987. PMC: 9233115. DOI: 10.1161/CIRCIMAGING.122.013987. View

5.
Berman D, Hachamovitch R, Kiat H, Cohen I, Cabico J, Wang F . Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: a basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol. 1995; 26(3):639-47. DOI: 10.1016/0735-1097(95)00218-S. View