» Articles » PMID: 19333605

Is Body Weight the Most Appropriate Criterion to Select Patients Eligible for Low-dose Pulmonary CT Angiography? Analysis of Objective and Subjective Image Quality at 80 KVp in 100 Patients

Overview
Journal Eur Radiol
Specialty Radiology
Date 2009 Apr 1
PMID 19333605
Citations 27
Authors
Affiliations
Soon will be listed here.
Abstract

The objective of this retrospective study was to assess image quality with pulmonary CT angiography (CTA) using 80 kVp and to find anthropomorphic parameters other than body weight (BW) to serve as selection criteria for low-dose CTA. Attenuation in the pulmonary arteries, anteroposterior and lateral diameters, cross-sectional area and soft-tissue thickness of the chest were measured in 100 consecutive patients weighing less than 100 kg with 80 kVp pulmonary CTA. Body surface area (BSA) and contrast-to-noise ratios (CNR) were calculated. Three radiologists analyzed arterial enhancement, noise, and image quality. Image parameters between patients grouped by BW (group 1: 0-50 kg; groups 2-6: 51-100 kg, decadally increasing) were compared. CNR was higher in patients weighing less than 60 kg than in the BW groups 71-99 kg (P between 0.025 and <0.001). Subjective ranking of enhancement (P = 0.165-0.605), noise (P = 0.063), and image quality (P = 0.079) did not differ significantly across all patient groups. CNR correlated moderately strongly with weight (R = -0.585), BSA (R = -0.582), cross-sectional area (R = -0.544), and anteroposterior diameter of the chest (R = -0.457; P < 0.001 all parameters). We conclude that 80 kVp pulmonary CTA permits diagnostic image quality in patients weighing up to 100 kg. Body weight is a suitable criterion to select patients for low-dose pulmonary CTA.

Citing Articles

Optimizing Arterial Vessel Contrast in Portal Venous Phase with Virtual Monoenergetic Images from Photon-Counting Detector CT Scans of the Abdomen-First Clinical Experiences.

Dillinger D, Overhoff D, Ayx I, Kaatsch H, Hagen A, Schonberg S Diagnostics (Basel). 2024; 14(6).

PMID: 38535047 PMC: 10969743. DOI: 10.3390/diagnostics14060627.


Impact of CT Photon-Counting Virtual Monoenergetic Imaging on Visualization of Abdominal Arterial Vessels.

Dillinger D, Overhoff D, Booz C, Kaatsch H, Piechotka J, Hagen A Diagnostics (Basel). 2023; 13(5).

PMID: 36900082 PMC: 10000913. DOI: 10.3390/diagnostics13050938.


Evaluation of rosmarinic acid against myocardial infarction in maternally separated rats.

Verma H, Bhattacharjee A, Shivavedi N, Nayak P Naunyn Schmiedebergs Arch Pharmacol. 2022; 395(10):1189-1207.

PMID: 35876905 DOI: 10.1007/s00210-022-02273-9.


Image quality, contrast enhancement and radiation dose of electrocardiograph- versus non-electrocardiograph-triggered computed tomography angiography of the aorta.

Wong Y, Ong C, Liang C, Tan C, Teo L Singapore Med J. 2021; 65(2):84-90.

PMID: 34688230 PMC: 10942131. DOI: 10.11622/smedj.2021166.


Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation.

Boccalini S, Harder A, Witsenburg M, Breur J, Krestin G, van Beynum I Eur Radiol Exp. 2020; 2(1):17.

PMID: 33252748 PMC: 6091724. DOI: 10.1186/s41747-018-0046-5.


References
1.
Livingston E, Lee S . Body surface area prediction in normal-weight and obese patients. Am J Physiol Endocrinol Metab. 2001; 281(3):E586-91. DOI: 10.1152/ajpendo.2001.281.3.E586. View

2.
Schaefer-Prokop C, Prokop M . CTPA for the diagnosis of acute pulmonary embolism during pregnancy. Eur Radiol. 2008; 18(12):2705-8. DOI: 10.1007/s00330-008-1158-8. View

3.
Nakaura T, Awai K, Yauaga Y, Nakayama Y, Oda S, Hatemura M . Contrast injection protocols for coronary computed tomography angiography using a 64-detector scanner: comparison between patient weight-adjusted- and fixed iodine-dose protocols. Invest Radiol. 2008; 43(7):512-9. DOI: 10.1097/RLI.0b013e3181727505. View

4.
Holmquist F, Nyman U . Eighty-peak kilovoltage 16-channel multidetector computed tomography and reduced contrast-medium doses tailored to body weight to diagnose pulmonary embolism in azotaemic patients. Eur Radiol. 2006; 16(5):1165-76. DOI: 10.1007/s00330-005-0117-x. View

5.
Wintersperger B, Jakobs T, Herzog P, Schaller S, Nikolaou K, Suess C . Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose. Eur Radiol. 2004; 15(2):334-41. DOI: 10.1007/s00330-004-2575-y. View