» Articles » PMID: 16447047

Eighty-peak Kilovoltage 16-channel Multidetector Computed Tomography and Reduced Contrast-medium Doses Tailored to Body Weight to Diagnose Pulmonary Embolism in Azotaemic Patients

Overview
Journal Eur Radiol
Specialty Radiology
Date 2006 Feb 1
PMID 16447047
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

The aim of this study was to assess the feasibility of minimising contrast-medium (CM) doses using 80-peak kilovoltage (kVp) 16-channel multidetector computed tomography (MDCT) with CM dose tailored to body weight, when diagnosing pulmonary embolism (PE) in azotaemic patients. Twenty-nine patients (68-93 years; 38-79 kg) with an estimated glomerular filtration rate of 12-49 ml/min underwent 80 kVp MDCT at a median dose of 200 mg iodine (I)/kg and 15 s injection time. Pulmonary artery (PA) enhancement where compared with our own reference material using 320 mg I/kg at 120 kVp and with reported figures in the literature at 120-140 kVp and a 42 g iodine CM dose. Median (1st and 3rd quartiles) values regarding CM dose were 12.2 (9.9-12.8) g iodine; density of left main and lower lobe segmental PA 339 (275-395) Hounsfield units (HU) and 354 (321-442) HU, respectively. Those enhancement values were similar to those obtained from the reference population at 120 kVp and those reported in the literature at 120-140 kVp. One patient had a transient increase in plasma creatinine. Three months' follow-up revealed deep venous thrombosis among 1/18 patients with negative results from computed tomography (CT). We conclude that 80 kVp 16-channel MDCT to diagnose PE in azotaemic patients may be performed with markedly reduced CM doses, implying a lesser risk for CM-induced nephropathy.

Citing Articles

A Universal Protocol for Abdominal CT Examinations Performed on a Photon-Counting Detector CT System: A Feasibility Study.

Zhou W, Michalak G, Weaver J, Gong H, Yu L, McCollough C Invest Radiol. 2020; 55(4):226-232.

PMID: 32049691 PMC: 7241672. DOI: 10.1097/RLI.0000000000000634.


High-pitch dual-source CT angiography without ECG-gating for imaging the whole aorta: intraindividual comparison with standard pitch single-source technique without ECG gating.

Manna C, Silva M, Cobelli R, Poggesi S, Rossi C, Sverzellati N Diagn Interv Radiol. 2017; 23(4):293-299.

PMID: 28703104 PMC: 5508953. DOI: 10.5152/dir.2017.16617.


Use of 100 kV versus 120 kV in computed tomography pulmonary angiography in the detection of pulmonary embolism: effect on radiation dose and image quality.

Gill M, Vijayananthan A, Kumar G, Jayarani K, Ng K, Sun Z Quant Imaging Med Surg. 2015; 5(4):524-33.

PMID: 26435916 PMC: 4559980. DOI: 10.3978/j.issn.2223-4292.2015.04.04.


Statistical model based iterative reconstruction in clinical CT systems. Part III. Task-based kV/mAs optimization for radiation dose reduction.

Li K, Gomez-Cardona D, Hsieh J, Lubner M, Pickhardt P, Chen G Med Phys. 2015; 42(9):5209-21.

PMID: 26328971 PMC: 4537484. DOI: 10.1118/1.4927722.


Prospective randomised comparison of diagnostic confidence and image quality with normal-dose and low-dose CT pulmonary angiography at various body weights.

Szucs-Farkas Z, Megyeri B, Christe A, Vock P, Heverhagen J, Schindera S Eur Radiol. 2014; 24(8):1868-77.

PMID: 24865694 DOI: 10.1007/s00330-014-3208-8.


References
1.
Sam 2nd A, Morasch M, Collins J, Song G, Chen R, Pereles F . Safety of gadolinium contrast angiography in patients with chronic renal insufficiency. J Vasc Surg. 2003; 38(2):313-8. DOI: 10.1016/s0741-5214(03)00315-x. View

2.
Schoellnast H, Deutschmann H, Fritz G, Stessel U, Schaffler G, Tillich M . MDCT angiography of the pulmonary arteries: influence of iodine flow concentration on vessel attenuation and visualization. AJR Am J Roentgenol. 2005; 184(6):1935-9. DOI: 10.2214/ajr.184.6.01841935. View

3.
Cigarroa R, Lange R, Williams R, Hillis L . Dosing of contrast material to prevent contrast nephropathy in patients with renal disease. Am J Med. 1989; 86(6 Pt 1):649-52. DOI: 10.1016/0002-9343(89)90437-3. View

4.
McCullough P, Wolyn R, Rocher L, Levin R, ONeill W . Acute renal failure after coronary intervention: incidence, risk factors, and relationship to mortality. Am J Med. 1997; 103(5):368-75. DOI: 10.1016/s0002-9343(97)00150-2. View

5.
. K/DOQI clinical practice guidelines for chronic kidney disease: evaluation, classification, and stratification. Am J Kidney Dis. 2002; 39(2 Suppl 1):S1-266. View