Evaluation of Fully 3-D Emission Mammotomography with a Compact Cadmium Zinc Telluride Detector

Overview
Date 2005 Jul 14
PMID 16011316
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

A compact, dedicated cadmium zinc telluride (CZT) gamma camera coupled with a fully three-dimensional (3-D) acquisition system may serve as a secondary diagnostic tool for volumetric molecular imaging of breast cancers, particularly in cases when mammographic findings are inconclusive. The developed emission mammotomography system comprises a medium field-of-view, quantized CZT detector and 3-D positioning gantry. The intrinsic energy resolution, sensitivity and spatial resolution of the detector are evaluated with Tc-99m (140 keV) filled flood sources, capillary line sources, and a 3-D frequency-resolution phantom. To mimic realistic human pendant, uncompressed breast imaging, two different phantom shapes of an average sized breast, and three different lesion diameters are imaged to evaluate the system for 3-D mammotomography. Acquisition orbits not possible with conventional emission, or transmission, systems are designed to optimize the viewable breast volume while improving sampling of the breast and anterior chest wall. Complications in camera positioning about the patient necessitate a compromise in these two orbit design criteria. Image quality is evaluated with signal-to-noise ratios and contrasts of the lesions, both with and without additional torso phantom background. Reconstructed results indicate that 3-D mammotomography, incorporating a compact CZT detector, is a promising, dedicated breast imaging technique for visualization of tumors < 1 cm in diameter. Additionally, there are no outstanding trajectories that consistently yield optimized quantitative lesion imaging parameters. Qualitatively, imaging breasts with realistic torso backgrounds (out-of-field activity) substantially alters image characteristics and breast morphology unless orbits which improve sampling are utilized. In practice, the sampling requirement may be less strict than initially anticipated.

Citing Articles

A dedicated breast-PET/CT scanner: Evaluation of basic performance characteristics.

Raylman R, Van Kampen W, Stolin A, Gong W, Jaliparthi G, Martone P Med Phys. 2018; 45(4):1603-1613.

PMID: 29389017 PMC: 5903937. DOI: 10.1002/mp.12780.


Preliminary evaluation of a novel energy-resolved photon-counting gamma ray detector.

Meng L, Tan J, Spartiotis K, Schulman T Nucl Instrum Methods Phys Res A. 2017; 604(3):548-554.

PMID: 28260825 PMC: 5333787. DOI: 10.1016/j.nima.2009.02.043.


Characterization of simulated incident scatter and the impact on quantification in dedicated breast single-photon emission computed tomography.

Mann S, Tornai M J Med Imaging (Bellingham). 2016; 2(3):033504.

PMID: 26839906 PMC: 4729114. DOI: 10.1117/1.JMI.2.3.033504.


Fisher Information Analysis of Depth-of-Interaction Estimation in Double-Sided Strip Detectors.

Salcin E, Barrett H, Barber H, Takeda S, Watanabe S, Takahashi T IEEE Trans Nucl Sci. 2015; 61(3):1243-1251.

PMID: 26160984 PMC: 4494127. DOI: 10.1109/TNS.2014.2317454.


Is SPECT or CT Based Attenuation Correction More Quantitatively Accurate for Dedicated Breast SPECT Acquired with Non-Traditional Trajectories?.

Perez K, Mann S, Pachon J, Madhav P, Tornai M IEEE Nucl Sci Symp Conf Rec (1997). 2015; 2010:2319-2324.

PMID: 25999683 PMC: 4437574. DOI: 10.1109/NSSMIC.2010.5874198.


References
1.
Coover L, Caravaglia G, Kuhn P . Scintimammography with dedicated breast camera detects and localizes occult carcinoma. J Nucl Med. 2004; 45(4):553-8. View

2.
Maublant J, De Latour M, Mestas D, Clemenson A, Charrier S, Feillel V . Technetium-99m-sestamibi uptake in breast tumor and associated lymph nodes. J Nucl Med. 1996; 37(6):922-5. View

3.
Mueller B, OConnor M, Blevis I, Rhodes D, Smith R, Collins D . Evaluation of a small cadmium zinc telluride detector for scintimammography. J Nucl Med. 2003; 44(4):602-9. View

4.
Scopinaro F, Pani R, De Vincentis G, Soluri A, Pellegrini R, Porfiri L . High-resolution scintimammography improves the accuracy of technetium-99m methoxyisobutylisonitrile scintimammography: use of a new dedicated gamma camera. Eur J Nucl Med. 1999; 26(10):1279-88. DOI: 10.1007/s002590050584. View

5.
Williams M, Goode A, Majewski S, Weisenberger A, Wojcik R . Performance of a PSPMT based detector for scintimammography. Phys Med Biol. 2000; 45(3):781-800. DOI: 10.1088/0031-9155/45/3/315. View