» Articles » PMID: 20224159

Observer Detection Limits for a Dedicated SPECT Breast Imaging System

Overview
Journal Phys Med Biol
Publisher IOP Publishing
Date 2010 Mar 13
PMID 20224159
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

An observer-based contrast-detail study is performed in an effort to evaluate the limits of object detectability using a dedicated CZT-based breast SPECT imaging system under various imaging conditions. A custom geometric contrast-resolution phantom was developed that can be used for both positive ('hot') and negative contrasts ('cold'). The 3 cm long fillable tubes are arranged in six sectors having equal inner diameters ranging from 1 mm to 6 mm with plastic wall thicknesses of <0.25 mm, on a pitch of twice their inner diameters. Scans of the activity filled tubes using simple circular trajectories are obtained in a 215 mL uniform water filled cylinder, varying the rod:background concentration ratios from 10:1 to 1:10 simulating a large range of biological uptake ratios. The rod phantom is then placed inside a non-uniformly shaped 500 mL breast phantom and scans are again acquired using both simple and complex 3D trajectories for similarly varying contrasts. Summed slice and contiguous multi-slice images are evaluated by five independent readers, identifying the smallest distinguishable rod for each concentration and experimental setup. Linear and quadratic regression is used to compare the resulting contrast-detail curves. Results indicate that in a moderately low-noise 500 mL background, using the SPECT camera having 2.5 mm intrinsic pixels, the mean detectable rod was approximately 3.4 mm at a 10:1 ratio, degrading to approximately 5.2 mm with the 2.5:1 concentration ratio. The smallest object detail was observed using a 45 degrees tilted trajectory acquisition. The complex 3D projected sine wave acquisition, however, had the most consistent combined intra- and inter-observer results, making it potentially the best imaging approach for consistent results.

Citing Articles

Evaluation of Cadmium-Zinc-Telluride Detector-based Single-Photon Emission Computed Tomography for Nuclear Cardiology: a Comparison with Conventional Anger Single-Photon Emission Computed Tomography.

Niimi T, Nanasato M, Sugimoto M, Maeda H Nucl Med Mol Imaging. 2017; 51(4):331-337.

PMID: 29242727 PMC: 5721085. DOI: 10.1007/s13139-017-0474-9.


Personalized estimates of radiation dose from dedicated breast CT in a diagnostic population and comparison with diagnostic mammography.

Vedantham S, Shi L, Karellas A, OConnell A, Conover D Phys Med Biol. 2013; 58(22):7921-36.

PMID: 24165162 PMC: 3872967. DOI: 10.1088/0031-9155/58/22/7921.


Radionuclide methods and instrumentation for breast cancer detection and diagnosis.

Surti S Semin Nucl Med. 2013; 43(4):271-80.

PMID: 23725989 PMC: 3755372. DOI: 10.1053/j.semnuclmed.2013.03.003.


Initial In Vivo Quantification of Tc-99m Sestamibi Uptake as a Function of Tissue Type in Healthy Breasts Using Dedicated Breast SPECT-CT.

Mann S, Perez K, McCracken E, Shah J, Wong T, Tornai M J Oncol. 2012; 2012:146943.

PMID: 22956950 PMC: 3431100. DOI: 10.1155/2012/146943.


Characterizing the contribution of cardiac and hepatic uptake in dedicated breast SPECT using tilted trajectories.

Perez K, Cutler S, Madhav P, Tornai M Phys Med Biol. 2010; 55(16):4721-34.

PMID: 20671354 PMC: 3266057. DOI: 10.1088/0031-9155/55/16/007.

References
1.
Waxman A . The role of (99m)Tc methoxyisobutylisonitrile in imaging breast cancer. Semin Nucl Med. 1997; 27(1):40-54. DOI: 10.1016/s0001-2998(97)80035-9. View

2.
Taillefer R . The role of 99mTc-sestamibi and other conventional radiopharmaceuticals in breast cancer diagnosis. Semin Nucl Med. 1999; 29(1):16-40. DOI: 10.1016/s0001-2998(99)80027-0. View

3.
Coover L, Caravaglia G, Kuhn P . Scintimammography with dedicated breast camera detects and localizes occult carcinoma. J Nucl Med. 2004; 45(4):553-8. View

4.
Maublant J, De Latour M, Mestas D, Clemenson A, Charrier S, Feillel V . Technetium-99m-sestamibi uptake in breast tumor and associated lymph nodes. J Nucl Med. 1996; 37(6):922-5. View

5.
Spanu A, Cottu P, Manca A, Chessa F, Sanna D, Madeddu G . Scintimammography with dedicated breast camera in unifocal and multifocal/multicentric primary breast cancer detection: a comparative study with SPECT. Int J Oncol. 2007; 31(2):369-77. View