Concentration of Simian Rotavirus SA-11 from Tap Water by Membrane Filtration and Organic Flocculation

Overview
Date 1983 Mar 1
PMID 6303220
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Simian rotavirus SA-11 was concentrated from tap water by adsorption to and elution from microporous filters, followed by organic flocculation. Two types of filters were compared for their ability to concentrate the virus. Both Zeta Plus 60S and Cox AA type M-780 filters were efficient for virus adsorption, but the efficiency of virus elution was higher with Zeta Plus than with Cox filters. Optimum conditions for virus recovery from Zeta Plus filters included an input water pH of 6.5 to 7.5 and the use of 3% beef extract (pH 9.0) for elution. Under these conditions, an average of 62 to 100% of the virus was recovered in the concentrate. Organic flocculation was used as a second-step concentration method, with average recoveries of 47 to 69%. When the two methods were used to concentrate small numbers (7 to 75 PFU/liter) of input rotavirus, an average of 75 +/- 40% recovery was achieved. With large volumes of input water, however, recovery was reduced to 16 +/- 7%.

Citing Articles

Cellulose-based virus-retentive filters: a review.

Junter G, Lebrun L Rev Environ Sci Biotechnol. 2020; 16(3):455-489.

PMID: 32214924 PMC: 7088658. DOI: 10.1007/s11157-017-9434-1.


Effects of humic materials on virus recovery from water.

Guttman-Bass N Appl Environ Microbiol. 1985; 49(5):1260-4.

PMID: 3159339 PMC: 238539. DOI: 10.1128/aem.49.5.1260-1264.1985.


Comparison of methods for rotavirus detection in water and results of a survey of Jerusalem wastewater.

Guttman-Bass N, Tchorsh Y, Marva E Appl Environ Microbiol. 1987; 53(4):761-7.

PMID: 3034156 PMC: 203752. DOI: 10.1128/aem.53.4.761-767.1987.


Development of a method for concentration of rotavirus and its application to recovery of rotaviruses from estuarine waters.

Rao V, Metcalf T, Melnick J Appl Environ Microbiol. 1986; 52(3):484-8.

PMID: 3021057 PMC: 203560. DOI: 10.1128/aem.52.3.484-488.1986.

References
1.
Farrah S, Goyal S, Gerba C, Conklin R, Wallis C, Melnick J . A simple method for concentration of enteroviruses and rotaviruses from cell culture harvests using membrane filters. Intervirology. 1978; 9(1):56-9. DOI: 10.1159/000148921. View

2.
Landry E, Vaughn J, Thomas M, Vicale T . Efficiency of beef extract for the recovery of poliovirus from wastewater effluents. Appl Environ Microbiol. 1978; 36(4):544-8. PMC: 243088. DOI: 10.1128/aem.36.4.544-548.1978. View

3.
Steinmann J . Detection of rotavirus in sewage. Appl Environ Microbiol. 1981; 41(4):1043-5. PMC: 243854. DOI: 10.1128/aem.41.4.1043-1045.1981. View

4.
Schoub B, Lecatsas G, Prozesky O . Antigenic relationship between human and simian rotaviruses. J Med Microbiol. 1977; 10(1):1-6. DOI: 10.1099/00222615-10-1-1. View

5.
Farrah S, Goyal S, Gerba C, Conklin R, Smith E . Comparison between adsorption of poliovirus and rotavirus by aluminum hydroxide and activated sludge flocs. Appl Environ Microbiol. 1978; 35(2):360-3. PMC: 242838. DOI: 10.1128/aem.35.2.360-363.1978. View