» Articles » PMID: 10841

Organic Flocculation: an Efficient Second-step Concentration Method for the Detection of Viruses in Tap Water

Overview
Date 1976 Oct 1
PMID 10841
Citations 84
Authors
Affiliations
Soon will be listed here.
Abstract

A method is described for second-step concentration of viruses from water. This method, combined with an adsorption-elution method, yields a mean recovery of about 75%

Citing Articles

Evaluation of alternative methods of tunnel composting (submitted by the European Composting Network) II.

Koutsoumanis K, Allende A, Bolton D, Bover-Cid S, Chemaly M, Herman L EFSA J. 2024; 22(4):e8745.

PMID: 38681740 PMC: 11046411. DOI: 10.2903/j.efsa.2024.8745.


Isolation and Genotyping of Adenoviruses from Wastewater and Diarrheal Samples in Egypt from 2016 to 2020.

Kamal Allayeh A, Al-Daim S, Ahmed N, El-Gayar M, Mostafa A Viruses. 2022; 14(10).

PMID: 36298747 PMC: 9609437. DOI: 10.3390/v14102192.


Infectious Pepper Mild Mottle Virus and Human Adenoviruses as Viral Indices in Sewage and Water Samples.

Rashed M, El-Senousy W, Sayed E, AlKhazindar M Food Environ Virol. 2022; 14(3):246-257.

PMID: 35713790 PMC: 9458564. DOI: 10.1007/s12560-022-09525-0.


Human Coronavirus NL63 Among Other Respiratory Viruses in Clinical Specimens of Egyptian Children and Raw Sewage Samples.

El-Senousy W, Shouman M Food Environ Virol. 2021; 13(3):322-328.

PMID: 34086254 PMC: 8176886. DOI: 10.1007/s12560-021-09479-9.


SARS-CoV-2 and other viruses in soil: An environmental outlook.

Anand U, Bianco F, Suresh S, Tripathi V, Nunez-Delgado A, Race M Environ Res. 2021; 198:111297.

PMID: 33971130 PMC: 8102436. DOI: 10.1016/j.envres.2021.111297.


References
1.
Jakubowski W, Hill Jr W, Clarke N . Comparative study of four microporous filters for concentrating viruses from drinking water. Appl Microbiol. 1975; 30(1):58-65. PMC: 187114. DOI: 10.1128/am.30.1.58-65.1975. View

2.
Farrah S, Gerba C, Wallis C, Melnick J . Concentration of viruses from large volumes of tap water using pleated membrane filters. Appl Environ Microbiol. 1976; 31(2):221-6. PMC: 169751. DOI: 10.1128/aem.31.2.221-226.1976. View

3.
Hill Jr W, Jakubowski W, Akin E, Clarke N . Detection of virus in water: sensitivity of the tentative standard method for drinking water. Appl Environ Microbiol. 1976; 31(2):254-61. PMC: 169756. DOI: 10.1128/aem.31.2.254-261.1976. View

4.
Berg G, Dahling D, Berman D . Recovery of small quantities of viruses from clean waters on cellulose nitrate membrane filters. Appl Microbiol. 1971; 22(4):608-14. PMC: 376372. DOI: 10.1128/am.22.4.608-614.1971. View

5.
Barron A, Olshevsky C, COHEN M . Characteristics of the BGM line of cells from African green monkey kidney. Brief report. Arch Gesamte Virusforsch. 1970; 32(4):389-92. DOI: 10.1007/BF01250067. View