Abstract

Simple, reliable, and efficient concentration of poliovirus from tap water was obtained with two types of electropositive filter media, one of which is available in the form of a pleated cartridge filter (Virozorb 1MDS). Virus adsorption from tap water between pH 3.5 and 7.5 was more efficient with electropositive filters than with Filterite filters. Elution of adsorbed viruses was more efficient with beef extract in glycine, pH 9.5, than with glycine-NaOH, pH 11.0. In paired comparative studies, electropositive filters, with adsorption at pH 7.5 and no added polyvalent cation salts, gave less variable virus concentration efficiencies than did Filterite filters with adsorption at pH 3.5 plus added MgCl2. Recovery of poliovirus from 1,000-liter tap water volumes was approximately 30% efficient with both Virozorb 1MDS and Filterite pleated cartridge filters, but the former were much simpler to use. The virus adsorption behavior of these filters appears to be related to their surface charge properties, with more electropositive filters giving more efficient virus adsorption from tap water at higher pH levels.

Citing Articles

An Appraisal of Bacteriophage Isolation Techniques from Environment.

Nair A, Ghugare G, Khairnar K Microb Ecol. 2021; 83(3):519-535.

PMID: 34136953 DOI: 10.1007/s00248-021-01782-z.


Chapter 9 The Detection of Waterborne Viruses.

Wyn-Jones P Perspect Med Virol. 2020; 17:177-204.

PMID: 32287592 PMC: 7114630. DOI: 10.1016/S0168-7069(07)17009-9.


Cellulose-based virus-retentive filters: a review.

Junter G, Lebrun L Rev Environ Sci Biotechnol. 2020; 16(3):455-489.

PMID: 32214924 PMC: 7088658. DOI: 10.1007/s11157-017-9434-1.


A Review of the Most Commonly Used Methods for Sample Collection in Environmental Surveillance of Poliovirus.

Matrajt G, Naughton B, Bandyopadhyay A, Meschke J Clin Infect Dis. 2018; 67(suppl_1):S90-S97.

PMID: 30376094 PMC: 6206110. DOI: 10.1093/cid/ciy638.


Atlantic salmon (Salmo salar L.) post-smolts challenged two or nine weeks after seawater-transfer show differences in their susceptibility to salmonid alphavirus subtype 3 (SAV3).

Jarungsriapisit J, Moore L, Taranger G, Nilsen T, Morton H, Fiksdal I Virol J. 2016; 13:66.

PMID: 27068518 PMC: 4827186. DOI: 10.1186/s12985-016-0520-8.


References
1.
Farrah S, Gerba C, Wallis C, Melnick J . Concentration of viruses from large volumes of tap water using pleated membrane filters. Appl Environ Microbiol. 1976; 31(2):221-6. PMC: 169751. DOI: 10.1128/aem.31.2.221-226.1976. View

2.
Jakubowski W, Hill Jr W, Clarke N . Comparative study of four microporous filters for concentrating viruses from drinking water. Appl Microbiol. 1975; 30(1):58-65. PMC: 187114. DOI: 10.1128/am.30.1.58-65.1975. View

3.
Mandel B . Characterization of type 1 poliovirus by electrophoretic analysis. Virology. 1971; 44(3):554-68. DOI: 10.1016/0042-6822(71)90369-2. View

4.
Glass J, Van Sluis R, Yanko W . Practical method for detecting poliovirus in anaerobic digester sludge. Appl Environ Microbiol. 1978; 35(5):983-5. PMC: 242967. DOI: 10.1128/aem.35.5.983-985.1978. View

5.
Wallis C, Melnick J . Concentration of enteroviruses on membrane filters. J Virol. 1967; 1(3):472-7. PMC: 375259. DOI: 10.1128/JVI.1.3.472-477.1967. View