» Articles » PMID: 11593222

Estimation of Coronary Flow Reserve with the Use of Dynamic Planar and SPECT Images of Tc-99m Tetrofosmin

Overview
Journal J Nucl Cardiol
Date 2001 Oct 11
PMID 11593222
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

Background: We developed a noninvasive method to examine coronary flow reserve with technetium 99m tetrofosmin based on the microsphere model. According to the microsphere model, myocardial blood flow (MBF) can be calculated by MBF = q / integral C(t)dt, where q is myocardial activity and C(t) is tracer concentration in blood. Because the ratio of integral C(t)dt at stress to rest is equal to the ratio of the first transit count in the pulmonary artery (PA) and attenuation factors were canceled out, we calculated the increase ratio of MBF (MBF(IR)).

Methods And Results: After injection of dipyridamole, tetrofosmin was injected as a bolus and serial dynamic planar images were obtained to measure the first transit count in PA (PAC). Myocardial single photon emission computed tomography was performed to measure the regional myocardial count (RMC). MBF(IR) was calculated as [(RMCs x PACr)/(RMCr x PACs) - 1] x 100, where r and s denote resting and stress conditions, respectively. In contrast, the increase in the myocardial uptake ratio (MUR(IR)) was defined as (RMCs x SCr/RMCr x SCs - 1) x 100, where SC is syringe count of tracer. The results were as follows: (1) The mean MBF of healthy subjects was 46.9% +/- 22.8%. (2) MBF(IR) of the infarcted region and ischemic region was significantly decreased (8.3% +/- 12.2% and 11.2% +/- 11.9%, respectively; P <.001). (3) MUR(IR) was significantly lower than MBF(IR) (14.1% +/- 21.2%; P <.001). (4) MBF(IR) decreased according to the heart rate at rest (r = 0.47; P <.05).

Conclusions: MBF(IR) is a potential parameter with which to evaluate coronary flow reserve when the changes of arterial input function during stress are considered.

Citing Articles

Improved detection of coronary artery disease by CZT regional coronary blood flow evaluation.

Lima R, Bezerra A, Andrade M, Domenico C, De Lorenzo A Front Nucl Med. 2024; 2:1072729.

PMID: 39354966 PMC: 11440858. DOI: 10.3389/fnume.2022.1072729.


Pathophysiologic Basis and Diagnostic Approaches for Ischemia With Non-obstructive Coronary Arteries: A Literature Review.

Fu B, Wei X, Lin Y, Chen J, Yu D Front Cardiovasc Med. 2022; 9:731059.

PMID: 35369287 PMC: 8968033. DOI: 10.3389/fcvm.2022.731059.


Quantitative myocardial perfusion from static cardiac and dynamic arterial CT.

Bindschadler M, Branch K, Alessio A Phys Med Biol. 2018; 63(10):105020.

PMID: 29701608 PMC: 6154784. DOI: 10.1088/1361-6560/aac0bd.


Comparison of coronary flow reserve estimated by dynamic radionuclide SPECT and multi-detector x-ray CT.

Marini C, Seitun S, Zawaideh C, Bauckneht M, Castiglione Morelli M, Ameri P J Nucl Cardiol. 2016; 24(5):1712-1721.

PMID: 27151303 DOI: 10.1007/s12350-016-0492-5.


Are SPECT measurements of myocardial blood flow and flow reserve ready for clinical use?.

Garcia E Eur J Nucl Med Mol Imaging. 2014; 41(12):2291-3.

PMID: 25311927 PMC: 4229445. DOI: 10.1007/s00259-014-2924-2.


References
1.
Klocke F . Measurements of coronary flow reserve: defining pathophysiology versus making decisions about patient care. Circulation. 1987; 76(6):1183-9. DOI: 10.1161/01.cir.76.6.1183. View

2.
Wilson R, Laughlin D, Ackell P, Chilian W, Holida M, Hartley C . Transluminal, subselective measurement of coronary artery blood flow velocity and vasodilator reserve in man. Circulation. 1985; 72(1):82-92. DOI: 10.1161/01.cir.72.1.82. View

3.
Hoffman J . A critical view of coronary reserve. Circulation. 1987; 75(1 Pt 2):I6-11. View

4.
Hutchins G, Schwaiger M, Rosenspire K, Krivokapich J, Schelbert H, Kuhl D . Noninvasive quantification of regional blood flow in the human heart using N-13 ammonia and dynamic positron emission tomographic imaging. J Am Coll Cardiol. 1990; 15(5):1032-42. DOI: 10.1016/0735-1097(90)90237-j. View

5.
Joye J, Schulman D . Clinical application of coronary flow reserve using an intracoronary Doppler guide wire. Cardiol Clin. 1997; 15(1):101-29. DOI: 10.1016/s0733-8651(05)70321-0. View