» Articles » PMID: 3886689

Bioluminescence Screening for Bacteriuria

Overview
Specialty Microbiology
Date 1985 Apr 1
PMID 3886689
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

A rapid screening test (45 min) for bacteriuria was evaluated in 1,000 clinical urine specimens. The test procedure is based upon firefly luciferase analysis of bacterial ATP and uses the Lumac kit and Lumac M2010 Biocounter (3M Co., St. Paul, Minn.). The procedure allows for removal and destruction of nonbacterial ATP and subsequent analysis of bacterial ATP by firefly luciferase with a single photon counter. Results, expressed in relative light units, were compared with actual CFU by the calibrated loop technique. Sensitivities and specificities were calculated separately for clean-catch midstream specimens and for urines obtained by catheterization. The sensitivity for 719 clean-catch specimens with a Lumac cutoff of greater than or equal to 500 relative light units, representing greater than or equal to 10(5) CFU/ml, was 93%. The sensitivity for 281 catheterized specimens with a Lumac cutoff of greater than or equal to 200 relative light units, representing greater than or equal to 10(4) CFU/ml, was 95%. There were 19 false-negative results in the 1,000 specimens tested; more than 50% of these were contaminated cultures and were not considered significant in determining bacteriuria. In conclusion, the Lumac bioluminescence assay is a reliable, rapid bacteriuria screening technique with the potential of reducing the laboratory cost and for reducing the turnaround time in processing negative urine cultures.

Citing Articles

Comparation of the effectiveness of conventional needle irrigation and photon-induced photoacoustic streaming with sodium hypochorite in the treatment of teeth with apical periodontitis: a randomized clinical trial.

Zhao J, Wu S, Huang Y, Zhao Y, Liu H, Jiang Q BMC Oral Health. 2024; 24(1):293.

PMID: 38431616 PMC: 10909256. DOI: 10.1186/s12903-024-04055-6.


An Intact Cell Bioluminescence-Based Assay for the Simple and Rapid Diagnosis of Urinary Tract Infection.

Reyes S, Le N, Fuentes M, Upegui J, Dikici E, Broyles D Int J Mol Sci. 2020; 21(14).

PMID: 32708609 PMC: 7404122. DOI: 10.3390/ijms21145015.


Rapid antimicrobial susceptibility determination of uropathogens in clinical urine specimens by use of ATP bioluminescence.

Ivancic V, Mastali M, Percy N, Gornbein J, Babbitt J, Li Y J Clin Microbiol. 2008; 46(4):1213-9.

PMID: 18272708 PMC: 2292911. DOI: 10.1128/JCM.02036-07.


Treatment of urinary tract infection. Clinical and economic considerations.

Plumridge R, Golledge C Pharmacoeconomics. 1996; 9(4):295-306.

PMID: 10160104 DOI: 10.2165/00019053-199609040-00003.


Simplified technique for detection of significant bacteriuria by microscopic examination of urine.

Cardoso C, Muraro C, Siqueira V, Guilhermetti M J Clin Microbiol. 1998; 36(3):820-3.

PMID: 9508322 PMC: 104635. DOI: 10.1128/JCM.36.3.820-823.1998.


References
1.
Welch W, Thompson L, Layman M, Southern Jr P . Evaluation of two bioluminescence-measuring instruments, the Turner Design and Lumac systems, for the rapid screening of urine specimens. J Clin Microbiol. 1984; 20(6):1165-70. PMC: 271538. DOI: 10.1128/jcm.20.6.1165-1170.1984. View

2.
Drow D, Baum C, Hirschfield G . Comparison of the Lumac and Monolight systems for detection of bacteriuria by bioluminescence. J Clin Microbiol. 1984; 20(4):797-801. PMC: 271433. DOI: 10.1128/jcm.20.4.797-801.1984. View

3.
Gorus F, SCHRAM E . Applications of bio- and chemiluminescence in the clinical laboratory. Clin Chem. 1979; 25(4):512-9. View

4.
KASS E . Pyelonephritis and bacteriuria. A major problem in preventive medicine. Ann Intern Med. 1962; 56:46-53. DOI: 10.7326/0003-4819-56-1-46. View

5.
KASS E . Bacteriuria and the diagnosis of infections of the urinary tract; with observations on the use of methionine as a urinary antiseptic. AMA Arch Intern Med. 1957; 100(5):709-14. DOI: 10.1001/archinte.1957.00260110025004. View