» Articles » PMID: 36354486

Eu-Chelate Polystyrene Microsphere-Based Lateral Flow Immunoassay Platform for Hs-CRP Detection

Overview
Specialty Biotechnology
Date 2022 Nov 10
PMID 36354486
Authors
Affiliations
Soon will be listed here.
Abstract

caused by viral or bacterial infection is a major threat to human health globally. Blood C-reactive protein (CRP) has been proven to be a sensitive indicator for the occurrence and development of inflammation. Furthermore, a tiny change of blood CRP concentration may portend chronic diseases; therefore, high-sensitivity CRP (hs-CRP) detection in a quantitative, rapid, user-friendly, and low-cost manner is highly demanded. In this paper, we developed a europium-chelate polystyrene microsphere (EuPSM)-based lateral flow immunoassay (LFIA) integrating with a benchtop fluorescence analyzer for hs-CRP detection. The optimization of the EuPSM-based LFIA was implemented through adjusting the antibody density on EuPSM from 100% to 60% of the saturated density. Finally, the limit of detection of 0.76 pg/mL and detection range of 0.025-250 ng/mL were obtained. Moreover, the clinical application capability of the proposed platform was validated through detecting CRP in clinical serum samples, showing high consistency with the results obtained from the clinical standard method. Hence, the proposed EuPSM-based LFIA has been verified to be well suitable for hs-CRP detection, while also showing great applicability for sensitively and rapidly detecting other biomarkers.

Citing Articles

Systematic optimization of UCNPs-LFA for Helicobacter pylori nucleic acid detection at point-of-care.

Jin B, Li S, Zhang C, Ma C, Hu J, Wang J Mikrochim Acta. 2024; 191(11):650.

PMID: 39370436 DOI: 10.1007/s00604-024-06730-5.


Changes in serum inflammatory factors in group B streptococcal infection and their predictive value for premature rupture of membranes complicated by chorioamnionitis.

Dong X, Chen X, Xue M, Zhang Y Biomark Med. 2024; 18(7):301-309.

PMID: 38623925 PMC: 11218798. DOI: 10.2217/bmm-2023-0588.


State-of-the-Art of Polymer/Fullerene C Nanocomposite Membranes for Water Treatment: Conceptions, Structural Diversity and Topographies.

Kausar A, Ahmad I, Maaza M, Eisa M Membranes (Basel). 2023; 13(1).

PMID: 36676834 PMC: 9864887. DOI: 10.3390/membranes13010027.

References
1.
Cai Y, Kang K, Liu Y, Wang Y, He X . Development of a lateral flow immunoassay of C-reactive protein detection based on red fluorescent nanoparticles. Anal Biochem. 2018; 556:129-135. DOI: 10.1016/j.ab.2018.06.017. View

2.
Zhan L, Guo S, Song F, Gong Y, Xu F, Boulware D . The Role of Nanoparticle Design in Determining Analytical Performance of Lateral Flow Immunoassays. Nano Lett. 2017; 17(12):7207-7212. PMC: 5747258. DOI: 10.1021/acs.nanolett.7b02302. View

3.
Li X, Pan Z, Li M, Jia X, Zhang S, Lin H . Europium chelate-labeled lateral flow assay for rapid and multiple detection of β-lactam antibiotics by the penicillin-binding protein. Anal Methods. 2020; 12(28):3645-3653. DOI: 10.1039/d0ay01140a. View

4.
Lv Y, Wu R, Feng K, Li J, Mao Q, Yuan H . Highly sensitive and accurate detection of C-reactive protein by CdSe/ZnS quantum dot-based fluorescence-linked immunosorbent assay. J Nanobiotechnology. 2017; 15(1):35. PMC: 5414212. DOI: 10.1186/s12951-017-0267-4. View

5.
Morioka K, Sato H, Kuboyama M, Yanagida A, Shoji A . Quantification of CRP in human serum using a handheld fluorescence detection system for capillary-based ELISA. Talanta. 2020; 224:121725. DOI: 10.1016/j.talanta.2020.121725. View