» Articles » PMID: 35069855

Continuous Glucose Monitoring Devices: A Brief Presentation (Review)

Abstract

As diabetes prevalence is continuously increasing, better management is needed to achieve blood glucose control, in order to prevent complications and lessen the burden of this disease. Since the first measurement of glycosuria at the beginning of the 1900s', huge advances were made in monitoring glycemia. Continuous glucose monitoring systems revolutionized diabetes management, especially for patients with type 1 diabetes. Avoiding glycemic variability and maintaining optimal glycemic control is crucial for the evolution of patients with type 1 diabetes. The usefulness of glycemic monitoring devices can be extended to patients with type 2 diabetes. It is also important to note that in those patients at risk of developing high glycemic variability (e.g. patients with advanced chronic kidney disease), continuous glycemic monitoring may improve their prognosis. These monitoring systems can be classified according to the analytical method, the degree of invasiveness, the data availability and the mode of usage. The technology is constantly improving in bioanalytical performance, biocompatibility, length of wearing time, safety and clinical features. The aim of this review was to briefly present the main characteristics of glucose biosensors, glucose monitoring systems and their clinically utility.

Citing Articles

Mind the Gap: Wearable Lactate and Glucose Monitors for Hospitalized Patients.

Guzzi J, Falter F, Kumar A, Perrino Jr A Cureus. 2025; 17(2):e78536.

PMID: 40062120 PMC: 11886925. DOI: 10.7759/cureus.78536.


Retained Continuous Glucose Monitor Sensor Wire Fragments Presenting as a Swollen Nodule of the Thigh.

Deng L, Galganski L, Krishnamurthy M JCEM Case Rep. 2025; 3(2):luae253.

PMID: 39911683 PMC: 11795673. DOI: 10.1210/jcemcr/luae253.


The Performance of Continuous Glucose Monitoring During the Intraoperative Period: A Scoping Review.

Lim H, Kim M, Kim N, Huh J, Jeong J, Hwang W J Clin Med. 2024; 13(20).

PMID: 39458119 PMC: 11508367. DOI: 10.3390/jcm13206169.


Criteria for Personalised Choice of a Continuous Glucose Monitoring System: An Expert Opinion.

Di Molfetta S, Rossi A, Boscari F, Irace C, Laviola L, Bruttomesso D Diabetes Ther. 2024; 15(11):2263-2278.

PMID: 39347900 PMC: 11467157. DOI: 10.1007/s13300-024-01654-y.


Targeting PI3K/AKT/mTOR and MAPK Signaling Pathways in Gastric Cancer.

Morgos D, Stefani C, Miricescu D, Greabu M, Stanciu S, Nica S Int J Mol Sci. 2024; 25(3).

PMID: 38339127 PMC: 10856016. DOI: 10.3390/ijms25031848.


References
1.
Tanne J, Schafer D, Khalid W, Parak W, Lisdat F . Light-controlled bioelectrochemical sensor based on CdSe/ZnS quantum dots. Anal Chem. 2011; 83(20):7778-85. DOI: 10.1021/ac201329u. View

2.
Didyuk O, Econom N, Guardia A, Livingston K, Klueh U . Continuous Glucose Monitoring Devices: Past, Present, and Future Focus on the History and Evolution of Technological Innovation. J Diabetes Sci Technol. 2020; 15(3):676-683. PMC: 8120065. DOI: 10.1177/1932296819899394. View

3.
Jayakumar R, Prabaharan M, Sudheesh Kumar P, Nair S, Tamura H . Biomaterials based on chitin and chitosan in wound dressing applications. Biotechnol Adv. 2011; 29(3):322-37. DOI: 10.1016/j.biotechadv.2011.01.005. View

4.
Timofte D, Dragos D, Balcangiu-Stroescu A, Tanasescu M, Balan D, Raducu L . Abdominal aortic calcification in predialysis patients: Contribution of traditional and uremia-related risk factors. Exp Ther Med. 2020; 20(1):97-102. PMC: 7271689. DOI: 10.3892/etm.2020.8607. View

5.
Rock J, GERENDE L . Dextrostix method for determination of blood glucose levels. A statistical evaluation. JAMA. 1966; 198(3):231-6. View