» Articles » PMID: 34159820

Woven EndoBridge Device for the Treatment of Ruptured Intracranial Aneurysms: A Systematic Review of Clinical and Angiographic Results

Overview
Publisher Sage Publications
Specialty Neurology
Date 2021 Jun 23
PMID 34159820
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Objective: The clinical outcome and angiographic outcome data of Woven EndoBridge (WEB) device for the treatment of ruptured intracranial aneurysms (IAs) are limited. We conducted a meta-analysis of the latest literature on the WEB device in the treatment of ruptured IAs.

Methods: A comprehensive literature search of 4 databases (PubMed, Web of Science, Cochrane library, and Embase) was conducted for studies published from January 1, 2010 to December 31, 2020. Two reviewers independently extracted variables (aneurysm and patient characteristics) using a prespecified data-collection sheet. Outcomes studied included initial and latest follow-up angiographic outcomes, technical success rate, perioperative mortality, retreated rate, perioperative re-bleeding, complication, intraoperative rupture, favorable neurologic outcome at discharge. We used random-effects model to pool the data.

Results: We finally presented the results of 7 articles including 276 patients with 283 aneurysms. Initial complete and adequate occlusion rate were 38% (95% CI, 25%-50%) and 98% (95% CI, 95%-100%), respectively. Latest follow-up complete and adequate occlusion rate were 61% (95% CI, 46%-75%) and 91% (95% CI, 84%-98%), respectively.Technical success rate was 99% (95% CI, 98%-100%). Perioperative mortality rates and perioperative re-bleeding rate were 9% (95% CI, 3%-15%) and 1% (95% CI, 0%-2%), respectively. Retreated rate was 6% (95% CI, 3%-10%). Overall and WEB treatment-related thromboembolic complication was 10% (95% CI, 6%-13%) and 7% (95% CI, 2%-12%), respectively. Intraoperative rupture rate was 3% (95% CI, 0%-6%).

Conclusion: Endovascular treatment of ruptured IAs with the WEB device has a good safety profile and an acceptable aneurysm occlusion rate.

Citing Articles

Intrasaccular Treatment of Intracranial Aneurysms: A Comprehensive Review.

Shao M, White T, Bassett J, Dowlati E, Mehta S, Werner C J Clin Med. 2024; 13(20).

PMID: 39458111 PMC: 11508718. DOI: 10.3390/jcm13206162.


Flow Diversion for Endovascular Treatment of Intracranial Aneurysms: Past, Present, and Future Directions.

Gaub M, Murtha G, Lafuente M, Webb M, Luo A, Birnbaum L J Clin Med. 2024; 13(14).

PMID: 39064207 PMC: 11278297. DOI: 10.3390/jcm13144167.


Variability patterns in dual antiplatelet therapy following endovascular repair of intracranial aneurysms: Insight into regimen heterogeneity and the need for a consensus.

Wadhwa A, Mensah E, Young M, Ogilvy C Acta Neurochir (Wien). 2024; 166(1):271.

PMID: 38888678 DOI: 10.1007/s00701-024-06137-4.


Woven EndoBridge versus stent-assisted coil embolization for the treatment of ruptured wide-necked aneurysms: A multicentric experience.

Rodriguez-Calienes A, Vivanco-Suarez J, Lu Y, Galecio-Castillo M, Gross B, Farooqui M Interv Neuroradiol. 2024; :15910199231223538.

PMID: 38166487 PMC: 11569807. DOI: 10.1177/15910199231223538.


Trends in Dual Antiplatelet Therapy Use for Neurointerventional Procedures for the Management of Intracranial Aneurysms.

Meyer B, Campos J, Collard de Beaufort J, Chen I, Khan M, Amin G Biomedicines. 2023; 11(8).

PMID: 37626730 PMC: 10452183. DOI: 10.3390/biomedicines11082234.


References
1.
Lodi Y, Latorre J, El-Zammar Z, Swarnkar A, Deshaies E, Fessler R . Stent assisted coiling of the ruptured wide necked intracranial aneurysm. J Neurointerv Surg. 2011; 4(4):281-6. DOI: 10.1136/neurintsurg-2011-010035. View

2.
van Rooij S, van Rooij W, Peluso J, Sluzewski M, Bechan R, Kortman H . WEB Treatment of Ruptured Intracranial Aneurysms: A Single-Center Cohort of 100 Patients. AJNR Am J Neuroradiol. 2017; 38(12):2282-2287. PMC: 7963751. DOI: 10.3174/ajnr.A5371. View

3.
Bartolini B, Blanc R, Pistocchi S, Redjem H, Piotin M . "Y" and "X" stent-assisted coiling of complex and wide-neck intracranial bifurcation aneurysms. AJNR Am J Neuroradiol. 2014; 35(11):2153-8. PMC: 7965174. DOI: 10.3174/ajnr.A4060. View

4.
Arthur A, Molyneux A, Coon A, Saatci I, Szikora I, Baltacioglu F . The safety and effectiveness of the Woven EndoBridge (WEB) system for the treatment of wide-necked bifurcation aneurysms: final 12-month results of the pivotal WEB Intrasaccular Therapy (WEB-IT) Study. J Neurointerv Surg. 2019; 11(9):924-930. PMC: 6824604. DOI: 10.1136/neurintsurg-2019-014815. View

5.
Armoiry X, Turjman F, Hartmann D, Sivan-Hoffmann R, Riva R, Labeyrie P . Endovascular Treatment of Intracranial Aneurysms with the WEB Device: A Systematic Review of Clinical Outcomes. AJNR Am J Neuroradiol. 2015; 37(5):868-72. PMC: 7960317. DOI: 10.3174/ajnr.A4611. View