» Articles » PMID: 24994823

WEB Intrasaccular Flow Disruptor-prospective, Multicenter Experience in 83 Patients with 85 Aneurysms

Overview
Specialty Neurology
Date 2014 Jul 5
PMID 24994823
Citations 59
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Purpose: The safety and efficacy of WEB flow disruption have been analyzed in small, retrospective series. The object of this study was to evaluate the safety and efficacy of WEB flow disruption in a large, multicenter, prospectively collected population.

Materials And Methods: Data from all patients treated with the WEB-DL device between June 2011 and October 2013 in 11 French neurointerventional centers were prospectively collected and retrospectively analyzed. Complications occurring during and after treatment were analyzed as well as morbidity and mortality at 1 month. Aneurysm occlusion status at the last follow-up was analyzed.

Results: Eighty-three patients with 85 aneurysms were included in this series. Technical success was achieved in 77 patients with 79 aneurysms (92.9%). Periprocedural complications were observed in 9 patients (10.8%), leading to permanent neurologic deficits in 3 (3.9%). Morbidity and mortality at 1 month were 1.3% and 0.0%, respectively. Angiographic follow-up was performed for 65/79 aneurysms (82.3%) 3-24 months after treatment (mean, 5.3 months). Complete aneurysm occlusion was observed in 37/65 aneurysms (56.9%); neck remnant, in 23/65 (35.4%); and aneurysm remnant, in 5/65 (7.7%).

Conclusions: In this large prospective series of patients, WEB flow disruption was a safe and efficient technique.

Citing Articles

The impact of pre-treatment aneurysm angulation. What happens with WEB devices at follow-up?.

Munoz R, Dazeo N, Garcia C, Janot K, Bankole N, Narata A Interv Neuroradiol. 2025; :15910199251316411.

PMID: 39871772 PMC: 11775925. DOI: 10.1177/15910199251316411.


The Impact of Postprocedural Anticoagulant Use in Patients Undergoing Woven EndoBridge: A Multicenter Propensity Score-Matched Study.

Musmar B, Salim H, Roy J, Adeeb N, Fuleihan A, Atallah E Transl Stroke Res. 2024; .

PMID: 39715904 DOI: 10.1007/s12975-024-01320-2.


Creation of a predictive calculator to determine adequacy of occlusion of the woven endobridge (WEB) device in intracranial aneurysms-A retrospective analysis of the WorldWide WEB Consortium database.

Musmar B, Adeeb N, Gendreau J, Horowitz M, Salim H, Sanmugananthan P Interv Neuroradiol. 2024; :15910199241267320.

PMID: 39127463 PMC: 11571495. DOI: 10.1177/15910199241267320.


Optimizing Photon-Counting Detector CT for Imaging Intracranial Aneurysms.

Rajendran K, Madhavan A AJNR Am J Neuroradiol. 2024; 45(10):1458-1460.

PMID: 39122465 PMC: 11448977. DOI: 10.3174/ajnr.A8400.


Treatment of large intracranial aneurysms using the Woven EndoBridge (WEB): a propensity score-matched analysis.

Musmar B, Salim H, Adeeb N, Aslan A, Aljeradat B, Diestro J Neurosurg Rev. 2024; 47(1):374.

PMID: 39083214 PMC: 11291542. DOI: 10.1007/s10143-024-02527-5.


References
1.
Lubicz B, Klisch J, Gauvrit J, Szikora I, Leonardi M, Liebig T . WEB-DL endovascular treatment of wide-neck bifurcation aneurysms: short- and midterm results in a European study. AJNR Am J Neuroradiol. 2014; 35(3):432-8. PMC: 7964738. DOI: 10.3174/ajnr.A3869. View

2.
Pierot L, Spelle L, Leclerc X, Cognard C, Bonafe A, Moret J . Endovascular treatment of unruptured intracranial aneurysms: comparison of safety of remodeling technique and standard treatment with coils. Radiology. 2009; 251(3):846-55. DOI: 10.1148/radiol.2513081056. View

3.
Pierot L, Cognard C, Ricolfi F, Anxionnat R . Mid-term anatomic results after endovascular treatment of ruptured intracranial aneurysms with Guglielmi detachable coils and Matrix coils: analysis of the CLARITY series. AJNR Am J Neuroradiol. 2011; 33(3):469-73. PMC: 7966434. DOI: 10.3174/ajnr.A2771. View

4.
Berge J, Biondi A, Machi P, Brunel H, Pierot L, Gabrillargues J . Flow-diverter silk stent for the treatment of intracranial aneurysms: 1-year follow-up in a multicenter study. AJNR Am J Neuroradiol. 2012; 33(6):1150-5. PMC: 8013262. DOI: 10.3174/ajnr.A2907. View

5.
Lubicz B, Mine B, Collignon L, Brisbois D, Duckwiler G, Strother C . WEB device for endovascular treatment of wide-neck bifurcation aneurysms. AJNR Am J Neuroradiol. 2013; 34(6):1209-14. PMC: 7964563. DOI: 10.3174/ajnr.A3387. View