» Articles » PMID: 33808168

The Influence of Ultrasound-Guided Technique Using a Catheter-Over-Needle on the Incidence of Accidental Intravascular Injection During Caudal Block-A Retrospective Case Series Study

Overview
Publisher MDPI
Specialty General Medicine
Date 2021 Apr 3
PMID 33808168
Authors
Affiliations
Soon will be listed here.
Abstract

This study was conducted to investigate the influence of an ultrasound-guided technique using a catheter-over-needle when an intravascular injection occurs in patients undergoing a caudal block. We retrospectively investigated 41 cases of an ultrasound-guided technique using an angiocatheter for caudal block. These had been performed between November 2019 through August 2020 to manage pain of lumbosacral origin. Under ultrasound guidance, after advancing the introducer needle through the sacrococcygeal ligament and then slowly withdrawing it, the outer catheter was continuously advanced into the sacral hiatus. We confirmed proper needle placement under fluoroscopic imaging, using 5 mL of contrast media. We assessed the contrast spread pattern with fluoroscopic imaging and checked it for the presence of intravascular injection. In all recruited cases, the catheter-over-needle was guided successfully to the sacral hiatus and into the caudal epidural space. There was 100% accuracy under ultrasound guidance, without intravascular uptake, as confirmed by contrast media fluoroscopy. The incidence of ventral spread was 84.2% above the S1 with 5 mL of contrast. The technique of using a catheter-over-needle under ultrasound induced successful block without intravascular injection. Thus, this technique is a reliable option for conventional caudal block.

References
1.
Chen C, Lew H, Tang S . Ultrasound-guided caudal epidural injection technique. Am J Phys Med Rehabil. 2014; 94(1):82-4. DOI: 10.1097/PHM.0000000000000047. View

2.
Koo B, Kang W, Park J, Lee S, Lee M, Cho A . Analysis of caudal epidurogram in single center: A preliminary study of lumbar radiculopathy management. Medicine (Baltimore). 2018; 97(41):e12810. PMC: 6203536. DOI: 10.1097/MD.0000000000012810. View

3.
Fukazawa K, Matsuki Y, Ueno H, Hosokawa T, Hirose M . Risk factors related to accidental intravascular injection during caudal anesthesia. J Anesth. 2014; 28(6):940-3. DOI: 10.1007/s00540-014-1840-8. View

4.
Lee J, Lee S, Sim W, Kim D, Lee S, Yun H . The influence of epidural catheter on the incidence of intravascular injection during caudal block. Skeletal Radiol. 2017; 46(12):1707-1713. DOI: 10.1007/s00256-017-2740-4. View

5.
Huang J . Disadvantages of ultrasound guidance in caudal epidural needle placement. Anesthesiology. 2005; 102(3):693. DOI: 10.1097/00000542-200503000-00034. View