We prospectively evaluated 316 caudal-approach epidural steroid injections given by staff radiologists and residents in our department over a 1-year period. Needle placement was checked with fluoroscopy and corrected if necessary. When the needle tip was within the sacral canal, nonionic contrast material was injected. If epidural contrast was not observed, the needle tip was repositioned. Of 111 procedures performed by physicians who had given fewer than 10 epidural steroid injections, 53 (47.7%) resulted in correct nonfluoroscopically directed placement of the needle. For physicians who had performed between 10 and 50 such procedures, 62 (53.4%) of 116 had correct nonfluoroscopically directed placement. For staff physicians, 55 (61.7%) of 89 placements were correct. Even when the sacral hiatus was easily palpated and a staff physician was confident that he or she was within the epidural space, fluoroscopy revealed incorrect placement 14.2% of the time (seven of 49 procedures). In addition, when the needle was positioned within the sacral canal and no blood was evident on Valsalva maneuver or aspiration, the injection was venous in 29 of 316 procedures (9.2%). The presence of blood on the needle stylus was not a reliable indicator of venous placement of the needle. Our findings indicate that fluoroscopy is essential for correct placement of epidural steroid injection. Contrast administration is necessary to avoid venous injection of steroids.

Citing Articles

Effectiveness of Ultrasonography- and Fluoroscopy-Guided Caudal Epidural Injections in the Management of Chronic Lumbar Disc Disease: A Retrospective Comparative Study.

Gupt S, Yadav G, Gupta A Cureus. 2024; 16(7):e64844.

PMID: 39156341 PMC: 11330279. DOI: 10.7759/cureus.64844.


Relationship of Abdominal Circumference and Trunk Length With Spinal Anesthesia Block Height in Geriatric Patients Undergoing Transurethral Resection of Prostate.

Yahya M, Ahmed A, Fatima I, Nasir M Cureus. 2023; 15(1):e33476.

PMID: 36751206 PMC: 9900462. DOI: 10.7759/cureus.33476.


Spine injections: the rationale for CT guidance.

Bogdanovic S, Sutter R, Zubler V Skeletal Radiol. 2022; 52(10):1853-1862.

PMID: 36149474 PMC: 10449983. DOI: 10.1007/s00256-022-04188-1.


Rationale for fluoroscopic guidance in spine injections.

Stratchko L, Pitts J, Symanski J, Ross A, Davis K, Monroe E Skeletal Radiol. 2022; 52(10):1841-1851.

PMID: 36102947 DOI: 10.1007/s00256-022-04181-8.


A Double-Blind, Randomized Controlled Pilot Trial to Assess the Analgesic Efficacy of Ultrasound-Guided Preemptive Caudal Morphine as an Adjunct to Bupivacaine for Lumbosacral Spine Surgeries in Adults.

Malviya A, Sawhney C, Baidya D, Bhattacharjee S, Kumar A, Farooque K Cureus. 2022; 14(8):e27647.

PMID: 36072182 PMC: 9437376. DOI: 10.7759/cureus.27647.