» Articles » PMID: 32845133

Dynamic Range Expansion by Gas-Phase Ion Fractionation and Enrichment for Imaging Mass Spectrometry

Overview
Journal Anal Chem
Specialty Chemistry
Date 2020 Aug 27
PMID 32845133
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

In the analysis of biological tissue by imaging mass spectrometry (IMS), the limit of detection and dynamic range are of paramount importance in obtaining experimental results that provide insight into underlying biological processes. Many important biomolecules are present in the tissue milieu in low concentrations and in complex mixtures with other compounds of widely ranging abundances, challenging the limits of analytical technologies. In many IMS experiments, the ion signal can be dominated by a few highly abundant ion species. On trap-based instrument platforms that accumulate ions prior to mass analysis, these high abundance ions can diminish the detection and dynamic range of lower abundance ions. Herein, we describe two strategies for combating these challenges during IMS experiments on a hybrid QhFT-ICR MS. In one iteration, the mass resolving capabilities of a quadrupole mass filter are used to selectively enrich ions of interest via a technique previously termed continuous accumulation of selected ions. Second, we have introduced a supplemental dipolar AC waveform to the quadrupole mass filter of a commercial QhFT-ICR mass spectrometer to perform selected ion ejection prior to the ion accumulation region. This setup allows the selective ejection of the most abundant ion species prior to ion accumulation, thereby greatly improving the molecular depth with which IMS can probe tissue samples. The gain in sensitivity of both of these approaches roughly scales with the number of accumulated laser shots up to the charge capacity of the ion accumulation cell. The efficiencies of these two strategies are described here by performing lipid imaging mass spectrometry analyses of a rat brain.

Citing Articles

Structural Elucidation and Relative Quantification of Fatty Acid Double Bond Positional Isomers in Biological Tissues Enabled by Gas-Phase Charge Inversion Ion/Ion Reactions.

Bonney J, Prentice B Anal Sens. 2024; 4(3).

PMID: 38827423 PMC: 11139046. DOI: 10.1002/anse.202300063.


Formation of multiple ion types during MALDI imaging mass spectrometry analysis of Mitragyna speciosa alkaloids in dosed rat brain tissue.

Liang Z, Guo Y, Ellin N, King T, Berthold E, Mukhopadhyay S Talanta. 2024; 274:125923.

PMID: 38569366 PMC: 11681430. DOI: 10.1016/j.talanta.2024.125923.


A multi-modal image fusion workflow incorporating MALDI imaging mass spectrometry and microscopy for the study of small pharmaceutical compounds.

Liang Z, Guo Y, Sharma A, McCurdy C, Prentice B bioRxiv. 2024; .

PMID: 38559145 PMC: 10980041. DOI: 10.1101/2024.03.12.584673.


Multiple ion isolation and accumulation events for selective chemical noise reduction and dynamic range enhancement in MALDI imaging mass spectrometry.

Scoggins 4th T, Specker J, Prentice B Analyst. 2024; 149(8):2459-2468.

PMID: 38525787 PMC: 11149414. DOI: 10.1039/d4an00160e.


Imaging and Structural Characterization of Phosphatidylcholine Isomers from Rat Brain Tissue Using Sequential Collision-Induced Dissociation/Electron-Induced Dissociation.

Yan T, Liang Z, Prentice B Anal Chem. 2023; 95(42):15707-15715.

PMID: 37818979 PMC: 10639000. DOI: 10.1021/acs.analchem.3c03077.


References
1.
Lisa Manier M, Reyzer M, Goh A, Dartois V, Via L, Barry 3rd C . Reagent precoated targets for rapid in-tissue derivatization of the anti-tuberculosis drug isoniazid followed by MALDI imaging mass spectrometry. J Am Soc Mass Spectrom. 2011; 22(8):1409-19. PMC: 3424619. DOI: 10.1007/s13361-011-0150-8. View

2.
Folch J, Lees M, SLOANE STANLEY G . A simple method for the isolation and purification of total lipides from animal tissues. J Biol Chem. 1957; 226(1):497-509. View

3.
Cha B, Blades M, Douglas D . An interface with a linear quadrupole ion guide for an electrospray-ion trap mass spectrometer system. Anal Chem. 2000; 72(22):5647-54. DOI: 10.1021/ac0004862. View

4.
Prentice B, Hart N, Phillips N, Haliyur R, Judd A, Armandala R . Imaging mass spectrometry enables molecular profiling of mouse and human pancreatic tissue. Diabetologia. 2019; 62(6):1036-1047. PMC: 6553460. DOI: 10.1007/s00125-019-4855-8. View

5.
Yang J, Caprioli R . Matrix sublimation/recrystallization for imaging proteins by mass spectrometry at high spatial resolution. Anal Chem. 2011; 83(14):5728-34. PMC: 3136623. DOI: 10.1021/ac200998a. View