» Articles » PMID: 25252102

Mass Selective Ion Transfer and Accumulation in Ion Trap Arrays

Overview
Journal Anal Chem
Specialty Chemistry
Date 2014 Sep 25
PMID 25252102
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

The concept and method for mass selective ion transfer and accumulation within quadrupole ion trap arrays have been demonstrated. Proof-of-concept experiments have been performed on two sets of ion trap arrays: (1) a linear ion trap with axial ion ejection plus a linear ion trap with radial ion ejection; (2) a linear ion trap with axial ion ejection plus a linear ion trap with axial ion ejection. In both sets of ion trap arrays, ions trapped in the first ion trap could be mass selectively transferred and accumulated into the second ion trap, while keeping other ions reserved in the first ion trap. Different operating modes have been implemented and tested, including transferring all ions, ions within a selected mass range, ions with a mass-to-charge ratio of 1, and randomly selected ions. Unit mass resolution for ion transfer and ∼90% ion transfer efficiency has been achieved. A new tandem mass spectrometry scheme for analyzing multiple precursor ions in a single sample injection has been demonstrated, which would improve instrument duty cycle and sample utilization rate (especially for very limited samples), potentially facilitate applications like single cell analyses, and improve electron transfer dissociation efficiency.

Citing Articles

Multiple ion isolation and accumulation events for selective chemical noise reduction and dynamic range enhancement in MALDI imaging mass spectrometry.

Scoggins 4th T, Specker J, Prentice B Analyst. 2024; 149(8):2459-2468.

PMID: 38525787 PMC: 11149414. DOI: 10.1039/d4an00160e.


Towards Higher Sensitivity of Mass Spectrometry: A Perspective From the Mass Analyzers.

Li C, Chu S, Tan S, Yin X, Jiang Y, Dai X Front Chem. 2022; 9:813359.

PMID: 34993180 PMC: 8724130. DOI: 10.3389/fchem.2021.813359.


Dynamic Range Expansion by Gas-Phase Ion Fractionation and Enrichment for Imaging Mass Spectrometry.

Prentice B, Ryan D, Grove K, Cornett D, Caprioli R, Spraggins J Anal Chem. 2020; 92(19):13092-13100.

PMID: 32845133 PMC: 8340028. DOI: 10.1021/acs.analchem.0c02121.


Valet Parking for Protein Ion Charge State Concentration: Ion/Molecule Reactions in Linear Ion Traps.

Foreman D, Bhanot J, Lee K, McLuckey S Anal Chem. 2020; 92(7):5419-5425.

PMID: 32100997 PMC: 7145756. DOI: 10.1021/acs.analchem.0c00146.


Improved Miniaturized Linear Ion Trap Mass Spectrometer Using Lithographically Patterned Plates and Tapered Ejection Slit.

Tian Y, Decker T, McClellan J, Bennett L, Li A, De la Cruz A J Am Soc Mass Spectrom. 2017; 29(2):213-222.

PMID: 28836122 DOI: 10.1007/s13361-017-1759-z.