Intensity Warping for Multisite MRI Harmonization

Overview
Journal Neuroimage
Specialty Radiology
Date 2020 Aug 18
PMID 32798678
Citations 25
Authors
Affiliations
Soon will be listed here.
Abstract

In multisite neuroimaging studies there is often unwanted technical variation across scanners and sites. These "scanner effects" can hinder detection of biological features of interest, produce inconsistent results, and lead to spurious associations. We propose mica (multisite image harmonization by cumulative distribution function alignment), a tool to harmonize images taken on different scanners by identifying and removing within-subject scanner effects. Our goals in the present study were to (1) establish a method that removes scanner effects by leveraging multiple scans collected on the same subject, and, building on this, (2) develop a technique to quantify scanner effects in large multisite studies so these can be reduced as a preprocessing step. We illustrate scanner effects in a brain MRI study in which the same subject was measured twice on seven scanners, and assess our method's performance in a second study in which ten subjects were scanned on two machines. We found that unharmonized images were highly variable across site and scanner type, and our method effectively removed this variability by aligning intensity distributions. We further studied the ability to predict image harmonization results for a scan taken on an existing subject at a new site using cross-validation.

Citing Articles

Are white matter hyperintensities associated with neuroborreliosis? The answer is twofold.

Lindland E, Rovang M, Solheim A, Andreassen S, Skarstein I, Dareez N Neuroradiology. 2024; 67(1):37-48.

PMID: 39422730 PMC: 11802615. DOI: 10.1007/s00234-024-03482-0.


Harmonization of Structural Brain Connectivity through Distribution Matching.

Zhou Z, Fischl B, Aganj I bioRxiv. 2024; .

PMID: 39314357 PMC: 11418962. DOI: 10.1101/2024.09.05.611489.


Investigation of ComBat Harmonization on Radiomic and Deep Features from Multi-Center Abdominal MRI Data.

Jia W, Li H, Ali R, Shanbhogue K, Masch W, Aslam A J Imaging Inform Med. 2024; .

PMID: 39284979 DOI: 10.1007/s10278-024-01253-0.


Neuroimage analysis using artificial intelligence approaches: a systematic review.

Bacon E, He D, Achi N, Wang L, Li H, Yao-Digba P Med Biol Eng Comput. 2024; 62(9):2599-2627.

PMID: 38664348 DOI: 10.1007/s11517-024-03097-w.


Learning multi-site harmonization of magnetic resonance images without traveling human phantoms.

Liu S, Yap P Commun Eng. 2024; 3.

PMID: 38420332 PMC: 10898625. DOI: 10.1038/s44172-023-00140-w.


References
1.
Wang H, Suh J, Das S, Pluta J, Craige C, Yushkevich P . Multi-Atlas Segmentation with Joint Label Fusion. IEEE Trans Pattern Anal Mach Intell. 2012; 35(3):611-23. PMC: 3864549. DOI: 10.1109/TPAMI.2012.143. View

2.
Keshavan A, Paul F, Beyer M, Zhu A, Papinutto N, Shinohara R . Power estimation for non-standardized multisite studies. Neuroimage. 2016; 134:281-294. PMC: 5656257. DOI: 10.1016/j.neuroimage.2016.03.051. View

3.
Shah M, Xiao Y, Subbanna N, Francis S, Arnold D, Collins D . Evaluating intensity normalization on MRIs of human brain with multiple sclerosis. Med Image Anal. 2011; 15(2):267-82. DOI: 10.1016/j.media.2010.12.003. View

4.
Zeis T, Graumann U, Reynolds R, Schaeren-Wiemers N . Normal-appearing white matter in multiple sclerosis is in a subtle balance between inflammation and neuroprotection. Brain. 2007; 131(Pt 1):288-303. DOI: 10.1093/brain/awm291. View

5.
Mirzaalian H, Ning L, Savadjiev P, Pasternak O, Bouix S, Michailovich O . Inter-site and inter-scanner diffusion MRI data harmonization. Neuroimage. 2016; 135:311-23. PMC: 5367052. DOI: 10.1016/j.neuroimage.2016.04.041. View