» Articles » PMID: 20378467

N4ITK: Improved N3 Bias Correction

Overview
Date 2010 Apr 10
PMID 20378467
Citations 2287
Authors
Affiliations
Soon will be listed here.
Abstract

A variant of the popular nonparametric nonuniform intensity normalization (N3) algorithm is proposed for bias field correction. Given the superb performance of N3 and its public availability, it has been the subject of several evaluation studies. These studies have demonstrated the importance of certain parameters associated with the B-spline least-squares fitting. We propose the substitution of a recently developed fast and robust B-spline approximation routine and a modified hierarchical optimization scheme for improved bias field correction over the original N3 algorithm. Similar to the N3 algorithm, we also make the source code, testing, and technical documentation of our contribution, which we denote as "N4ITK," available to the public through the Insight Toolkit of the National Institutes of Health. Performance assessment is demonstrated using simulated data from the publicly available Brainweb database, hyperpolarized (3)He lung image data, and 9.4T postmortem hippocampus data.

Citing Articles

An analysis of performance bottlenecks in MRI preprocessing.

Dugre M, Chatelain Y, Glatard T Gigascience. 2025; 14.

PMID: 40072903 PMC: 11899568. DOI: 10.1093/gigascience/giae098.


Risk stratification in neuroblastoma patients through machine learning in the multicenter PRIMAGE cohort.

Lozano-Montoya J, Jimenez-Pastor A, Fuster-Matanzo A, Weiss G, Cerda-Alberich L, Veiga-Canuto D Front Oncol. 2025; 15:1528836.

PMID: 40061893 PMC: 11886962. DOI: 10.3389/fonc.2025.1528836.


Functional differentiation of the default and frontoparietal control networks predicts individual differences in creative achievement: evidence from macroscale cortical gradients.

Sassenberg T, Jung R, DeYoung C Cereb Cortex. 2025; 35(3).

PMID: 40056422 PMC: 11890067. DOI: 10.1093/cercor/bhaf046.


Exploring a recurrence model for atypical meningioma based on multiparametric MRI radiomic and clinical characteristics: a multicenter retrospective cohort study.

Song D, Wei Q, Zhao S, Lou Y, Zhang K, Duan C Radiat Oncol. 2025; 20(1):30.

PMID: 40045333 PMC: 11884072. DOI: 10.1186/s13014-025-02613-y.


Evaluating fusion models for predicting occult lymph node metastasis in tongue squamous cell carcinoma.

Li W, Li Y, Wang L, Yang M, Iikubo M, Huang N Eur Radiol. 2025; .

PMID: 40042648 DOI: 10.1007/s00330-025-11473-9.


References
1.
Fichele S, Woodhouse N, Swift A, Said Z, Paley M, Kasuboski L . MRI of helium-3 gas in healthy lungs: posture related variations of alveolar size. J Magn Reson Imaging. 2004; 20(2):331-5. DOI: 10.1002/jmri.20104. View

2.
Vovk U, Pernus F, Likar B . A review of methods for correction of intensity inhomogeneity in MRI. IEEE Trans Med Imaging. 2007; 26(3):405-21. DOI: 10.1109/TMI.2006.891486. View

3.
Sled J, Zijdenbos A, Evans A . A nonparametric method for automatic correction of intensity nonuniformity in MRI data. IEEE Trans Med Imaging. 1998; 17(1):87-97. DOI: 10.1109/42.668698. View

4.
Manjon J, Lull J, Carbonell-Caballero J, Garcia-Marti G, Marti-Bonmati L, Robles M . A nonparametric MRI inhomogeneity correction method. Med Image Anal. 2007; 11(4):336-45. DOI: 10.1016/j.media.2007.03.001. View

5.
Aubert-Broche B, Evans A, Collins L . A new improved version of the realistic digital brain phantom. Neuroimage. 2006; 32(1):138-45. DOI: 10.1016/j.neuroimage.2006.03.052. View