» Articles » PMID: 31427614

A Flow Through Device for Simultaneous Dielectrophoretic Cell Trapping and AC Electroporation

Overview
Journal Sci Rep
Specialty Science
Date 2019 Aug 21
PMID 31427614
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

Isolation of cells and their transfection in a controlled manner is an integral step in cell biotechnology. Electric field approaches such as dielectrophoresis (DEP) offers a more viable method for targeted immobilization of cells without any labels. For transfection of cells to incorporate exogenous materials, electrical methods such as electroporation, are preferred over chemical and viral delivery methods since they minimally affect cell viability and can target many types. However prior approaches to both methods required multiple excitation sources, an AC source for DEP-based trapping and another DC source for electroporation. In this paper, we present a first of its kind flow through lab-on-chip platform using a single AC excitation source for combined trapping using negative dielectrophoresis (nDEP) and AC electroporation. Use of AC fields for electroporation eliminates the unwanted side effects of electrolysis or joule heating at electrodes compared to DC electroporation. Adjusting the flow rate and the electrical parameters of the incident AC field precisely controls the operation (trap, trap with electroporation and release). The platform has been validated through trapping and simultaneous transfection of HEK-293 embryonic kidney cells with a plasmid vector containing a fluorescent protein tag. Numerical scaling analysis is provided that indicates promise for individual cell trapping and electroporation using low voltage AC fields.

Citing Articles

Analysis of Cell Dielectrophoretic Properties Using Isomotive Creek-Gap Electrode Device.

Tada S, Sato N Sensors (Basel). 2024; 24(23).

PMID: 39686217 PMC: 11644872. DOI: 10.3390/s24237681.


Recent Advances in Dielectrophoretic Manipulation and Separation of Microparticles and Biological Cells.

Yao J, Zhao K, Lou J, Zhang K Biosensors (Basel). 2024; 14(9).

PMID: 39329792 PMC: 11429840. DOI: 10.3390/bios14090417.


On-chip dielectrophoretic single-cell manipulation.

Tian Z, Wang X, Chen J Microsyst Nanoeng. 2024; 10(1):117.

PMID: 39187499 PMC: 11347631. DOI: 10.1038/s41378-024-00750-0.


Single-Cell RNA Sequencing in Organ and Cell Transplantation.

Abedini-Nassab R, Taheri F, Emamgholizadeh A, Naderi-Manesh H Biosensors (Basel). 2024; 14(4).

PMID: 38667182 PMC: 11048310. DOI: 10.3390/bios14040189.


Portable dielectrophoresis for biology: ADEPT facilitates cell trapping, separation, and interactions.

Julius L, Akgul D, Krishnan G, Falk F, Korvink J, Badilita V Microsyst Nanoeng. 2024; 10:29.

PMID: 38434587 PMC: 10907756. DOI: 10.1038/s41378-024-00654-z.


References
1.
Kim J, Cho K, Shin Y, Jung N, Chung C, Chang J . A multi-channel electroporation microchip for gene transfection in mammalian cells. Biosens Bioelectron. 2007; 22(12):3273-7. DOI: 10.1016/j.bios.2007.02.009. View

2.
Soffe R, Baratchi S, Tang S, Nasabi M, McIntyre P, Mitchell A . Analysing calcium signalling of cells under high shear flows using discontinuous dielectrophoresis. Sci Rep. 2015; 5:11973. PMC: 4648442. DOI: 10.1038/srep11973. View

3.
Lyu C, Wang J, Powell-Palm M, Rubinsky B . Simultaneous electroporation and dielectrophoresis in non-electrolytic micro/nano-electroporation. Sci Rep. 2018; 8(1):2481. PMC: 5802840. DOI: 10.1038/s41598-018-20535-6. View

4.
Bhagat A, Hou H, Li L, Lim C, Han J . Pinched flow coupled shear-modulated inertial microfluidics for high-throughput rare blood cell separation. Lab Chip. 2011; 11(11):1870-8. DOI: 10.1039/c0lc00633e. View

5.
Hibino M, Itoh H, Kinosita Jr K . Time courses of cell electroporation as revealed by submicrosecond imaging of transmembrane potential. Biophys J. 1993; 64(6):1789-800. PMC: 1262513. DOI: 10.1016/S0006-3495(93)81550-9. View