Changes of the Solution PH Due to Exposure by High-voltage Electric Pulses

Overview
Publisher Elsevier
Specialty Biochemistry
Date 2005 Jun 22
PMID 15967404
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

The change of the pH of a NaCl solution (139-149 mM NaCl) buffered with 5-15 mM sodium phosphates (pH 7.4) during electromanipulation was studied. It has been determined that an increase in the pH value of electroporation solution of a whole chamber volume, caused by the application of electric field pulses, commonly used in cell electromanipulation procedures, can exceed 1-2 pH units. Several materials for the cathode were tested. In all cases a stainless steel anode was utilized. The aluminum cathode gave a two-fold greater DeltapH in comparison with platinum, copper or stainless steel cathodes. In addition, a substantial release of aluminum (up to 1 mg/l) from the cathode was observed. It has also been found that the shift in pH depended on the medium conductivity: DeltapH of the solution, in which sucrose was substituted for NaCl, was about 5 times less. On the basis of the results obtained here, to avoid the plausible undesirable consequences of the cathodic electrolysis processes, in particular under the conditions of strong electric treatment, it could be recommended that chambers with aluminum electrodes not be utilized and one should use strongly buffered solutions of low conductivity and alternating current (sine or square wave) bipolar electric pulses.

Citing Articles

Efficient electroporation in primary cells with PEDOT:PSS electrodes.

Gharia A, Bradfield C, Jenkins E, Fraser I, Malliaras G Sci Adv. 2024; 10(43):eado5042.

PMID: 39454003 PMC: 11506140. DOI: 10.1126/sciadv.ado5042.


The Effect of Partial Electrical Insulation of the Tip and Active Needle Length of Monopolar Irreversible Electroporation Electrodes on the Electric Field Line Pattern and Temperature Gradient to Improve Treatment Control.

Hogenes A, Slump C, Te Riet O G Scholten G, Stommel M, Futterer J, Verdaasdonk R Cancers (Basel). 2023; 15(17).

PMID: 37686556 PMC: 10486353. DOI: 10.3390/cancers15174280.


Pulse Parameters and Thresholds for (ir)Reversible Electroporation on Hepatocellular Carcinoma Cells .

Lindelauf K, Baragona M, Baumann M, Maessen R, Ritter A Technol Cancer Res Treat. 2023; 22:15330338221136694.

PMID: 36600679 PMC: 9829997. DOI: 10.1177/15330338221136694.


Dielectric Dispersion Modulated Sensing of Yeast Suspension Electroporation.

Pintarelli G, da Silva J, Yang W, Suzuki D Sensors (Basel). 2022; 22(5).

PMID: 35270958 PMC: 8914882. DOI: 10.3390/s22051811.


Cytotoxicity of a Cell Culture Medium Treated with a High-Voltage Pulse Using Stainless Steel Electrodes and the Role of Iron Ions.

Saulis G, Rodaite-Riseviciene R, Saule R Membranes (Basel). 2022; 12(2).

PMID: 35207105 PMC: 8877239. DOI: 10.3390/membranes12020184.