» Articles » PMID: 30963270

Deep Learning-based Image Restoration Algorithm for Coronary CT Angiography

Overview
Journal Eur Radiol
Specialty Radiology
Date 2019 Apr 10
PMID 30963270
Citations 86
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: The purpose of this study was to compare the image quality of coronary computed tomography angiography (CTA) subjected to deep learning-based image restoration (DLR) method with images subjected to hybrid iterative reconstruction (IR).

Methods: We enrolled 30 patients (22 men, 8 women) who underwent coronary CTA on a 320-slice CT scanner. The images were reconstructed with hybrid IR and with DLR. The image noise in the ascending aorta, left atrium, and septal wall of the ventricle was measured on all images and the contrast-to-noise ratio (CNR) in the proximal coronary arteries was calculated. We also generated CT attenuation profiles across the proximal coronary arteries and measured the width of the edge rise distance (ERD) and the edge rise slope (ERS). Two observers visually evaluated the overall image quality using a 4-point scale (1 = poor, 4 = excellent).

Results: On DLR images, the mean image noise was lower than that on hybrid IR images (18.5 ± 2.8 HU vs. 23.0 ± 4.6 HU, p < 0.01) and the CNR was significantly higher (p < 0.01). The mean ERD was significantly shorter on DLR than on hybrid IR images, whereas the mean ERS was steeper on DLR than on hybrid IR images. The mean image quality score for hybrid IR and DLR images was 2.96 and 3.58, respectively (p < 0.01).

Conclusions: DLR reduces the image noise and improves the image quality at coronary CTA.

Key Points: • Deep learning-based image restoration is a new technique that employs the deep convolutional neural network for image quality improvement. • Deep learning-based restoration reduces the image noise and improves image quality at coronary CT angiography. • This method may allow for a reduction in radiation exposure.

Citing Articles

Super-resolution deep learning reconstruction for improved quality of myocardial CT late enhancement.

Takafuji M, Kitagawa K, Mizutani S, Hamaguchi A, Kisou R, Sasaki K Jpn J Radiol. 2025; .

PMID: 40072715 DOI: 10.1007/s11604-025-01760-2.


CZT-based photon-counting-detector CT with deep-learning reconstruction: image quality and diagnostic confidence for lung tumor assessment.

Sasaki T, Kuno H, Nomura K, Muramatsu Y, Aokage K, Samejima J Jpn J Radiol. 2025; .

PMID: 40053285 DOI: 10.1007/s11604-025-01759-9.


Diagnostic value of deep learning reconstruction-based subtraction CT-FFR in patients with calcified-related stenosis or stent implantation.

Xu C, Yi Y, Xu M, Zou L, Wang M, Wang Y Quant Imaging Med Surg. 2025; 15(2):1599-1612.

PMID: 39995698 PMC: 11847182. DOI: 10.21037/qims-24-1366.


From imaging to computational domains for physics-driven molecular biology simulations: Hindered diffusion in platelet masses.

House C, Huang Z, Shankar K, Young S, Roberts M, Diamond S bioRxiv. 2025; .

PMID: 39975354 PMC: 11839050. DOI: 10.1101/2025.02.06.636817.


High-resolution deep learning reconstruction for coronary CTA: compared efficacy of stenosis evaluation with other methods at in vitro and in vivo studies.

Matsuyama T, Nagata H, Ozawa Y, Ito Y, Kimata H, Fujii K Eur Radiol. 2025; .

PMID: 39903239 DOI: 10.1007/s00330-025-11376-9.


References
1.
Birnbaum B, Hindman N, Lee J, Babb J . Multi-detector row CT attenuation measurements: assessment of intra- and interscanner variability with an anthropomorphic body CT phantom. Radiology. 2006; 242(1):109-19. DOI: 10.1148/radiol.2421052066. View

2.
Hausleiter J, Meyer T, Hermann F, Hadamitzky M, Krebs M, Gerber T . Estimated radiation dose associated with cardiac CT angiography. JAMA. 2009; 301(5):500-7. DOI: 10.1001/jama.2009.54. View

3.
Dreyer K, Geis J . When Machines Think: Radiology's Next Frontier. Radiology. 2017; 285(3):713-718. DOI: 10.1148/radiol.2017171183. View

4.
Tatsugami F, Higaki T, Sakane H, Fukumoto W, Kaichi Y, Iida M . Coronary Artery Stent Evaluation with Model-based Iterative Reconstruction at Coronary CT Angiography. Acad Radiol. 2017; 24(8):975-981. DOI: 10.1016/j.acra.2016.12.020. View

5.
Tatsugami F, Husmann L, Herzog B, Burkhard N, Valenta I, Gaemperli O . Evaluation of a body mass index-adapted protocol for low-dose 64-MDCT coronary angiography with prospective ECG triggering. AJR Am J Roentgenol. 2009; 192(3):635-8. DOI: 10.2214/AJR.08.1390. View