» Articles » PMID: 16794164

Accuracy of 64-MDCT in the Diagnosis of Ischemic Heart Disease

Overview
Specialties Oncology
Radiology
Date 2006 Jun 24
PMID 16794164
Citations 74
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: The aim of this study was to evaluate the potential clinical value of a new generation of 64-MDCT systems with that of invasive coronary angiography in the diagnosis of coronary artery disease (CAD).

Subjects And Methods: Seventy-two consecutive patients with known or suspected CAD underwent both 64-MDCT and quantitative coronary angiography (QCA). A CT system with acquisition of 64 slices per gantry rotation was used with a spatial resolution of 0.4 x 0.4 x 0.4 mm and a gantry rotation time of 330 milliseconds. Sensitivity, specificity, and diagnostic accuracy of 64-MDCT in the detection or exclusion of CAD were evaluated on both a per patient and a per segment basis.

Results: Sixty-eight of 72 coronary CT angiograms (CTAs) (94%) were of diagnostic image quality. QCA showed significant CAD (i.e., one or more stenoses in > 50%) in 57% (39/68) and nonsignificant disease or healthy CTAs in 43% (29/68) of the patients. Sensitivity, specificity, and the negative predictive value (NPV) of 64-MDCT per patient were 97%, 79%, and 96%, respectively. Per segment, 923 of 1,020 coronary artery segments were assessable (90%). For the detection of stenoses of more than 50% and more than 75% per segment, 64-MDCT showed a sensitivity of 82% and 86%, respectively. Per segment, specificity and NPV were as high as 95% and 97%, respectively.

Conclusion: In clinical routine, coronary CTA will primarily be used for risk stratification on a per patient basis. In the present study, coronary 64-MDCT showed a high diagnostic accuracy on both per patient and per segment analyses.

Citing Articles

Research Status and Direction of Chronic Obstructive Pulmonary Disease Complicated with Coronary Heart Disease: A Bibliometric Analysis from 2005 to 2024.

Bian H, Zhu S, Xing W, Qi L, Xue J, Peng X Int J Chron Obstruct Pulmon Dis. 2025; 20():23-41.

PMID: 39802036 PMC: 11724669. DOI: 10.2147/COPD.S495326.


Comparison of coronary CT angiography and invasive coronary angiography results.

Tekinhatun M, Akbudak I, Ozbek M, Turmak M Ir J Med Sci. 2024; 193(5):2239-2248.

PMID: 38965116 PMC: 11450059. DOI: 10.1007/s11845-024-03745-y.


Super resolution deep learning reconstruction for coronary CT angiography: A structured phantom study.

Higaki T, Tatsugami F, Ohana M, Nakamura Y, Kawashita I, Awai K Eur J Radiol Open. 2024; 12:100570.

PMID: 38828096 PMC: 11140562. DOI: 10.1016/j.ejro.2024.100570.


Evaluation of four computed tomography reconstruction algorithms using a coronary artery phantom.

Sawamura S, Kato S, Funama Y, Oda S, Mochizuki H, Inagaki S Quant Imaging Med Surg. 2024; 14(4):2870-2883.

PMID: 38617144 PMC: 11007503. DOI: 10.21037/qims-23-1204.


Super-resolution deep learning reconstruction at coronary computed tomography angiography to evaluate the coronary arteries and in-stent lumen: an initial experience.

Orii M, Sone M, Osaki T, Ueyama Y, Chiba T, Sasaki T BMC Med Imaging. 2023; 23(1):171.

PMID: 37904089 PMC: 10617195. DOI: 10.1186/s12880-023-01139-7.