» Articles » PMID: 30488396

Achieving Stable Electrospray Ionization Mass Spectrometry Detection from Microfluidic Chips

Overview
Specialty Molecular Biology
Date 2018 Nov 30
PMID 30488396
Authors
Affiliations
Soon will be listed here.
Abstract

The past two decades have witnessed remarkable advances in the development of microfluidic devices as bioanalytical platforms for the analysis of biological molecules. The implementation of mass spectrometry (MS) detection systems on these devices has become inevitable, and various chip-MS ionization interfaces have been developed. As electrospray ionization (ESI) is particularly relevant for the analysis of large biological molecules such as proteins or peptides, efforts have focused on advancing interfaces that meet the demands of nano-separation techniques that are typically used prior to MS detection. Achieving stable ESI conditions that enable sensitive MS detection is, however, not trivial, especially when the spray is generated from a microfabricated platform. This chapter is aimed at providing a step-by-step protocol for producing stable and efficient electrospray sample ionization from microfluidic chips that are used for capillary electrophoresis (CE) separations.

References
1.
Lazar I, Ramsey R, Jacobson S, Foote R, Ramsey J . Novel microfabricated device for electrokinetically induced pressure flow and electrospray ionization mass spectrometry. J Chromatogr A. 2000; 892(1-2):195-201. DOI: 10.1016/s0021-9673(00)00335-6. View

2.
Ho J, Tan M, Go D, Yeo L, Friend J, Chang H . Paper-based microfluidic surface acoustic wave sample delivery and ionization source for rapid and sensitive ambient mass spectrometry. Anal Chem. 2011; 83(9):3260-6. DOI: 10.1021/ac200380q. View

3.
Li J, Thibault P, Bings N, Skinner C, Wang C, Colyer C . Integration of microfabricated devices to capillary electrophoresis-electrospray mass spectrometry using a low dead volume connection: application to rapid analyses of proteolytic digests. Anal Chem. 1999; 71(15):3036-45. DOI: 10.1021/ac981420y. View

4.
Chambers A, Mellors J, Henley W, Ramsey J . Monolithic integration of two-dimensional liquid chromatography-capillary electrophoresis and electrospray ionization on a microfluidic device. Anal Chem. 2011; 83(3):842-9. PMC: 3059363. DOI: 10.1021/ac102437z. View

5.
Xue Q, Dunayevskiy Y, Foret F, Karger B . Integrated multichannel microchip electrospray ionization mass spectrometry: analysis of peptides from on-chip tryptic digestion of melittin. Rapid Commun Mass Spectrom. 1997; 11(12):1253-6. DOI: 10.1002/(SICI)1097-0231(199708)11:12<1253::AID-RCM17>3.0.CO;2-6. View