Characterization of Micromachined Hollow Tips for Two-dimensional Nanoelectrospray Mass Spectrometry

Overview
Specialty Chemistry
Date 2003 Feb 6
PMID 12569444
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

In this work an improved design of chip-based nanoelectrospray nozzles is reported. Two-dimensional matrices of out-of-plane 10 microm i.d. silicon dioxide tips with a tapered shape were manufactured using deep reactive ion etching technology. Using a peptide sample, six micromachined tips and six commercially pulled silica capillary tips were compared employing an ion trap mass spectrometer. At a flow rate of 100 nL/min, the detectability obtained was approximately the same for the two types of tips. The relative standard deviation of the signal-to-noise ratio for the peptides between six different tips was on average 22% for the micromachined tips and 45% for the pulled capillary tips. The usefulness of the micromachined tips for analysis of non-covalent protein-ligand complexes was demonstrated by the analysis of a sample of RNase A and cytidine 2'-monophosphate. In another test, analyzing a tryptic digest of 1 pmol/microL cytochrome C, 18 peptides corresponding to a 82% sequence coverage were detected. Using MS/MS, the whole sequence of an 11 amino acid cytochrome C fragment was obtained. Computer simulations were performed on the shape and magnitude of the electrical field around micromachined and pulled capillary tips. To reach the threshold electric field density at the tip apex required to initiate an electrospray, a higher electrospray voltage was needed for the chip-based tips compared with pulled capillary tips. This is due to the influence of the chip base.

Citing Articles

Achieving Stable Electrospray Ionization Mass Spectrometry Detection from Microfluidic Chips.

Lazar I Methods Mol Biol. 2018; 1906:225-237.

PMID: 30488396 PMC: 7384444. DOI: 10.1007/978-1-4939-8964-5_15.


Analytical performance of a venturi-assisted array of micromachined ultrasonic electrosprays coupled to ion trap mass spectrometry for the analysis of peptides and proteins.

Hampton C, Forbes T, Varady M, Meacham J, Fedorov A, Degertekin F Anal Chem. 2007; 79(21):8154-61.

PMID: 17914864 PMC: 2543123. DOI: 10.1021/ac071297n.


An open design microfabricated nib-like nanoelectrospray emitter tip on a conducting silicon substrate for the application of the ionization voltage.

Le Gac S, Rolando C, Arscott S J Am Soc Mass Spectrom. 2005; 17(1):75-80.

PMID: 16352441 DOI: 10.1016/j.jasms.2005.09.003.


A novel nib-like design for microfabricated nanospray tips.

Le Gac S, Cren-Olive C, Rolando C, Arscott S J Am Soc Mass Spectrom. 2004; 15(3):409-12.

PMID: 14998544 DOI: 10.1016/j.jasms.2003.11.001.