» Articles » PMID: 30178548

Determination of Hemoglobin Mass in Humans by Measurement of CO Uptake During Inhalation of a CO-air Mixture: a Proof of Concept Study

Overview
Journal Physiol Rep
Specialty Physiology
Date 2018 Sep 5
PMID 30178548
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Measuring hemoglobin mass (Hbmass) using the carbon monoxide (CO) bolus rebreathing method is frequently used in research but has yet to be widely used in the clinical practice. The estimation of an adequate CO bolus may be difficult in patients with unknown Hbmass. In the present pilot study, a progressive inhalation technique for CO that leads to a linear individual adjusted COHb increase was evaluated. Sixteen healthy test subjects participated in the study (preliminary investigation: six; main study: ten). The reliability and validity of the new method were evaluated using multiple measurements of Hbmass with and without a defined blood donation and compared to a CO bolus method. The participants inhaled a CO-air mixture (CO concentration: 1500 ppm) for a specific breathing duration. The CO uptake and COHb change were determined simultaneously. The typical error (reliability) in the repeated measurements was 2.4% (CI ± 4.7). The mean difference between the new method and the bolus method was 34 g (±41; P = 0.026). The measured hemoglobin loss in 490 mL of blood was 74 g (±35), and the calculated hemoglobin loss was 77 g (±4) (mean difference 3 g ± 34; P = 0.820). The new method was reliable and valid in a proof of concept study with healthy subjects. The total amount of CO and as a result the COHb increase is individually adjustable. Future studies in clinical settings are needed to determine if the method could be used in disease-specific pathologies associated with changes in Hbmass.

Citing Articles

A simple and novel equation to estimate the degree of bleeding in haemorrhagic shock: mathematical derivation and preliminary validation.

Chon S, Lee M, Oh W, Park Y, Kwon J, Kim K Korean J Physiol Pharmacol. 2022; 26(3):195-205.

PMID: 35477547 PMC: 9046898. DOI: 10.4196/kjpp.2022.26.3.195.


Determination of hemoglobin mass in humans by measurement of CO uptake during inhalation of a CO-air mixture: a proof of concept study.

Falz R, Busse M Physiol Rep. 2018; 6(17):e13849.

PMID: 30178548 PMC: 6121115. DOI: 10.14814/phy2.13849.

References
1.
Christensen P, Waever Rasmussen J, Winther Henneberg S . Accuracy of a new bedside method for estimation of circulating blood volume. Crit Care Med. 1993; 21(10):1535-40. DOI: 10.1097/00003246-199310000-00023. View

2.
Keiser S, Siebenmann C, Bonne T, Sorensen H, Robach P, Lundby C . The carbon monoxide re-breathing method can underestimate Hbmass due to incomplete blood mixing. Eur J Appl Physiol. 2013; 113(9):2425-30. DOI: 10.1007/s00421-013-2681-0. View

3.
Karlsen T, Leinan I, Aamot I, Dalen H, Stoylen A . Safety of the CO-Rebreathing Method in Patients with Coronary Artery Disease. Med Sci Sports Exerc. 2015; 48(1):33-8. DOI: 10.1249/MSS.0000000000000729. View

4.
. Recommended methods for measurement of red-cell and plasma volume: International Committee for Standardization in Haematology. J Nucl Med. 1980; 21(8):793-800. View

5.
Schibler A, Hall G, Businger F, Reinmann B, Wildhaber J, CERNELC M . Measurement of lung volume and ventilation distribution with an ultrasonic flow meter in healthy infants. Eur Respir J. 2002; 20(4):912-8. DOI: 10.1183/09031936.02.00226002. View