» Articles » PMID: 30091510

Surface Patterning of a Novel PEG-functionalized Poly-l-lactide Polymer to Improve Its Biocompatibility: Applications to Bioresorbable Vascular Stents

Overview
Date 2018 Aug 10
PMID 30091510
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Today, research in the field of bioresorbable vascular stents (BVS) not only focusses on a new material being nontoxic but also tries to enhance its biocompatibility in terms of endothelialization potential and hemocompatibility. To this end, we used picosecond laser ablation technology as a single-step and contactless method for surface microstructuring of a bioresorbable polymer which can be utilized in stent manufacture. The method works on all materials via fast material removal, can be easily adapted for micropatterning of tubular or more complex sample shapes and scaled up by means of micropatterning of metal molds for manufacturing. Here, picosecond laser ablation was applied to a bioresorbable, biologically inactive and polyethylene glycol-modified poly-L-lactide polymer (PEGylated PLLA) to generate parallel microgrooves with varying geometries. The different patterns were thoroughly evaluated by a series of cyto- and hemocompatibility tests revealing that all surfaces were non-toxic and non-hemolytic. More importantly, patterns with 20 to 25 µm wide and 6 to 7 µm deep grooves significantly enhanced endothelial cell adhesion in comparison to samples with smaller grooves. Here, human cardiac microvascular endothelial cells were found to align along the groove direction, which is thought to encourage endothelialization of intraluminal surfaces of BVS. © 2018 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 00B: 000-000, 2018. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 624-634, 2019.

Citing Articles

Advances in Conductive Biomaterials for Cardiac Tissue Engineering: Design, Fabrication, and Functional Integration.

Khan T, Vadivel G, Ayyasamy K, Murugesan G, Sebaey T Polymers (Basel). 2025; 17(5).

PMID: 40076113 PMC: 11902469. DOI: 10.3390/polym17050620.


biocompatibility analysis of protein-resistant amphiphilic polysulfobetaines as coatings for surgical implants in contact with complex body fluids.

Karthauser J, Gruhn D, Martinez Guajardo A, Kopecz R, Babel N, Stervbo U Front Bioeng Biotechnol. 2024; 12:1403654.

PMID: 39086500 PMC: 11288920. DOI: 10.3389/fbioe.2024.1403654.


Assessment of degradability and endothelialization of modified poly L-lactic acid (PLLA) atrial septal defect (ASD) occluders over time in vivo.

Chen J, Xie Y, Li Y, Chen X, Fu M, Liu Y J Cardiothorac Surg. 2023; 18(1):283.

PMID: 37817186 PMC: 10566106. DOI: 10.1186/s13019-023-02401-3.


Hemocompatibility Evaluation of Thai Silk Fibroin and Its Improvement with Low Molecular Weight Heparin Immobilization.

Fungmongkonsatean T, Jongjitwimol J, Paensuwan P, Nuamchit T, Siriwittayawan D, Kanokpanont S Polymers (Basel). 2022; 14(14).

PMID: 35890719 PMC: 9319666. DOI: 10.3390/polym14142943.


The Mechanisms of Restenosis and Relevance to Next Generation Stent Design.

Clare J, Ganly J, Bursill C, Sumer H, Kingshott P, de Haan J Biomolecules. 2022; 12(3).

PMID: 35327622 PMC: 8945897. DOI: 10.3390/biom12030430.


References
1.
van Oeveren W . Obstacles in haemocompatibility testing. Scientifica (Cairo). 2013; 2013:392584. PMC: 3820147. DOI: 10.1155/2013/392584. View

2.
Biela S, Su Y, Spatz J, Kemkemer R . Different sensitivity of human endothelial cells, smooth muscle cells and fibroblasts to topography in the nano-micro range. Acta Biomater. 2009; 5(7):2460-6. DOI: 10.1016/j.actbio.2009.04.003. View

3.
Wang J, He Y, Maitz M, Collins B, Xiong K, Guo L . A surface-eroding poly(1,3-trimethylene carbonate) coating for fully biodegradable magnesium-based stent applications: toward better biofunction, biodegradation and biocompatibility. Acta Biomater. 2013; 9(10):8678-89. DOI: 10.1016/j.actbio.2013.02.041. View

4.
Lu J, Rao M, MacDonald N, Khang D, Webster T . Improved endothelial cell adhesion and proliferation on patterned titanium surfaces with rationally designed, micrometer to nanometer features. Acta Biomater. 2007; 4(1):192-201. DOI: 10.1016/j.actbio.2007.07.008. View

5.
Eskin S, Ives C, McIntire L, Navarro L . Response of cultured endothelial cells to steady flow. Microvasc Res. 1984; 28(1):87-94. DOI: 10.1016/0026-2862(84)90031-1. View