Children with congenital or acquired heart disease can be exposed to relatively high lifetime cumulative doses of ionizing radiation from necessary medical imaging procedures including radiography, fluoroscopic procedures including diagnostic and interventional cardiac catheterizations, electrophysiology examinations, cardiac computed tomography (CT) studies, and nuclear cardiology examinations. Despite the clinical necessity of these imaging studies, the related ionizing radiation exposure could pose an increased lifetime attributable cancer risk. The Image Gently "Have-A-Heart" campaign is promoting the appropriate use of medical imaging studies in children with congenital or acquired heart disease while minimizing radiation exposure. The focus of this manuscript is to provide a comprehensive review of radiation dose management and CT performance in children with congenital or acquired heart disease.

Citing Articles

Postnatal Outcomes in Prenatally Detected Vascular Rings.

Das N, Pedamallu H, Young K, Rosenthal L, Valika T, Popescu A Pediatr Cardiol. 2025; .

PMID: 39994015 DOI: 10.1007/s00246-025-03803-x.


Radiation dose proportions of localizer radiograph and bolus tracking in low-dose pediatric cardiothoracic computed tomography.

Goo H, Goo S Pediatr Radiol. 2025; 55(3):466-478.

PMID: 39888399 DOI: 10.1007/s00247-025-06163-z.


Multimodality Imaging Evaluation of Diseases of the Pulmonic Valve and Right Ventricular Outflow Tract for the Adult Cardiologist.

Murphy S, Sultana S, Zern E, Tower-Rader A, Churchill J, Stefanescu Schmidt A Circ Cardiovasc Imaging. 2025; 18(2):e017126.

PMID: 39801475 PMC: 11835535. DOI: 10.1161/CIRCIMAGING.124.017126.


Cumulative radiation dose from medical imaging in paediatric congenital heart disease patients with epicardial cardiac implantable electronic devices.

Aboyewa O, Laternser C, Popescu A, Murphy N, Shah D, Monge M Eur Heart J Imaging Methods Pract. 2024; 2(1):qyae060.

PMID: 39045197 PMC: 11251694. DOI: 10.1093/ehjimp/qyae060.


Impact of Appropriate Use Criteria for Cross-Sectional Imaging on Medical Decision-Making in Patients with Conotruncal Defects.

Sheets R, Hashemi S, Smith C, Rodriguez 3rd F, Sachdeva R, Wilson H Pediatr Cardiol. 2024; .

PMID: 38951144 DOI: 10.1007/s00246-024-03568-9.


References
1.
Rappaport B, Suresh S, Hertz S, Evers A, Orser B . Anesthetic neurotoxicity--clinical implications of animal models. N Engl J Med. 2015; 372(9):796-7. DOI: 10.1056/NEJMp1414786. View

2.
Bae K, Hong C, Takahashi N, Gutierrez F, Sharkey A, Hirsch R . Multi-detector row computed tomographic angiography in pediatric heart transplant recipients: Initial observations. Transplantation. 2004; 77(4):599-602. DOI: 10.1097/01.tp.0000112437.07994.46. View

3.
Han B, Rigsby C, Leipsic J, Bardo D, Abbara S, Ghoshhajra B . Computed Tomography Imaging in Patients with Congenital Heart Disease, Part 2: Technical Recommendations. An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT): Endorsed by the Society of Pediatric Radiology (SPR).... J Cardiovasc Comput Tomogr. 2015; 9(6):493-513. DOI: 10.1016/j.jcct.2015.07.007. View

4.
Einstein A, Berman D, Min J, Hendel R, Gerber T, Carr J . Patient-centered imaging: shared decision making for cardiac imaging procedures with exposure to ionizing radiation. J Am Coll Cardiol. 2014; 63(15):1480-9. PMC: 3994983. DOI: 10.1016/j.jacc.2013.10.092. View

5.
Young C, Taylor A, Owens C . Paediatric cardiac computed tomography: a review of imaging techniques and radiation dose consideration. Eur Radiol. 2010; 21(3):518-29. DOI: 10.1007/s00330-010-2036-8. View